Topic 1Bulk quantification of crystallinity1 of 4
A Raman reading measures crystalline indomethacin down to about 1%, but it reads low below 25%.
Mix pure crystalline and glassy indomethacin in known ratios, record the Raman spectrum of the powder and compare the heights of two Raman bands (carbonyl bands at 1698 and 1680 cm⁻¹). Twelve independent mixtures from 1 to 99% crystalline fell on a line of slope 1.008, with 99% reading 98.7% and 1% reading 0.9% taylor1998a R7, R8, R9.
moderateModerate: calibration and validation agree over 1–99%, but the low end reads low, several table values are inconsistent, and it was tested on one drug with one instrument taylor1998a K1, X3, X4.
Low end of the validation set: every mean lies below the actual value. At 25% crystalline the mean was 21.3. taylor1998a R9, X4
For your drug
- Record Raman spectra of the pure crystal and the glass and look for one band for each form.
- Calibrate with mixtures whose particle size matches your samples, validate on independent mixtures below 25% and at the extremes, and take the detection limit from the mixtures.
taylor1998a C19, C21, C36, C37
How it works and key numbers
- The crystal has a narrow carbonyl band at 1698 cm⁻¹ and the glass a broad one at 1680 cm⁻¹, so each form contributes a little at the other's position taylor1998a C10, C11, C12.
- A two-band model corrects for the overlap, using factors of 0.052 and 0.401 measured on the pure forms taylor1998a E3, R5.
- The corrected ratio of the two band heights gives the crystalline fraction of any mixture taylor1998a E4, E5.
- Why the low end reads low was not measured taylor1998a X4.
Evidence: data, conditions and papers
Finding F1. A two-band FT-Raman ratio gave a linear calibration of crystallinity for indomethacin mixtures from 0 to 100% and detected about 1% of either form, but readings between 2 and 25% crystalline ran low
In short. Taylor and Zografi read the carbonyl band of γ-crystalline indomethacin (1698 cm⁻¹) against that of the quench-cooled glass (1680 cm⁻¹) and corrected for the overlap of the two bands with band-factor ratios of 0.052 and 0.401 and a fitted ratio of 2.72 taylor1998a R4, R5, R6. Calibration mixtures then fell on a line of slope 1.01 (r = 0.9996), and twelve independent mixtures from 1 to 99% crystalline on a line of slope 1.008 and intercept −0.0139, with 99% reading 98.7% and 1% reading 0.9% taylor1998a R7, R8, R9. Between 2 and 25% crystalline the means read 0.8–3.7 points below the actual value, the authors put the detection limit at about 1% and called their estimated 2% quantitation limit "too low" taylor1998a R9, R14, C21, X4, F3.
Type. observation in one drug (indomethacin), one instrument Strength. calibration and independent validation agree over 1–99% taylor1998a K1, but the low end reads low, several table values are inconsistent, and the milled-sample values rest on the mixture calibration alone taylor1998a X3, X4, X9.
How it was shown
Taylor and Zografi (1998) mixed 100% crystalline γ-indomethacin and quench-cooled glass at known ratios and recorded each powder by FT-Raman through the vial wall taylor1998a M1, M2, P4, P6. They read the carbonyl bands at 1698 cm⁻¹ (crystal) and 1680 cm⁻¹ (glass), corrected for their overlap with a two-band model, calibrated on twelve mixtures and validated on twelve independent ones taylor1998a C9, C10, E3, P7, P11, R6, R9.
What the data show
The overlap factors were 0.052 and 0.401 taylor1998a R5. The independent mixtures gave slope 1.008 and intercept −0.0139 taylor1998a R8. From 93 to 99% crystalline the means were within 0.5 points, but every composition at or below 75% read low, by up to 3.7 points, and at 25, 7, 3 and 2% the whole five-run range lay below the actual value taylor1998a R9, X4. The authors put detection at about 1% and called the estimated 2% quantitation limit "too low" taylor1998a R14, C21.
| actual crystalline, % | Raman mean, % | ids |
|---|---|---|
| 99 | 98.7 | taylor1998a R9 |
| 75 | 73.6 | taylor1998a R9 |
| 25 | 21.3 | taylor1998a R9 |
| 7 | 5.9 | taylor1998a R9 |
| 3 | 2.2 | taylor1998a R9 |
| 1 | 0.9 | taylor1998a R9 |

The validation line fits well at both ends; look at the low-end points that sit below it taylor1998a R8, R9.
Why
The crystal has a narrow carbonyl band and the glass a broad one, so the crystal adds little at 1680 cm⁻¹ and the glass more at 1698 cm⁻¹ (the authors' interpretation) taylor1998a C10, C11, C12, R5. The cause of the low readings at 2–25% crystalline was not measured taylor1998a X4.
Limits and transfer
One compound, powders below 150 µm, no polymer and no test of particle-size effects taylor1998a M1, M2, C19; several table values are inconsistent taylor1998a X3. For another drug, find a band pair for the two forms, build size-matched mixtures, validate below 25% and at the extremes, and take the detection limit from the mixtures, not from a pure form alone taylor1998a C21, C36, C37.
How it was shown
Taylor and Zografi (1998) asked whether FT-Raman spectroscopy can quantify the degree of crystallinity, and so the amorphous content, of a drug powder across the whole composition range, including small amounts of either form taylor1998a C3, C4. The two reference forms were γ-indomethacin from Sigma, a fine powder below 150 µm taken as 100% crystalline, and amorphous indomethacin made by melting at 165 °C for 5 min, quench cooling in liquid nitrogen, warming under vacuum, light pulverizing below 150 µm and storage over P₂O₅ at −20 °C taylor1998a M1, M2, P1, C6. XRPD and DSC characterized both: sharp peaks against a halo, a glass transition of 45 °C for the glass, and fusion at 161 °C with 109 J/g for the crystal taylor1998a R1, M1, M2. Mixtures of known ratio were prepared geometrically to 500 mg in a Wig-L-Bug capsule without the ball, sealed in a glass vial of about 1 cm diameter and stored at −20 °C and 0% RH; agitating the crystal in the capsule did not change its DSC enthalpy of fusion taylor1998a P4, R2, C7. A Bruker RFS 100 FT-Raman system (1064 nm, spot of about 1 mm, about 450 mW, 100 scans from 4000 to 50 cm⁻¹ at 4 cm⁻¹, backscattered light, Ge detector) recorded each powder through the glass wall taylor1998a P6. The benzoyl carbonyl bands at 1698 cm⁻¹ (crystal) and 1680 cm⁻¹ (glass) were chosen for quantitation; because the amorphous band is broadened, each measured height contains a share of the other form, which the authors treat with the two-band model of Kontoyannis et al. taylor1998a C9, C10, E3. Twelve calibration mixtures covering 0–100% gave the last unknown ratio, and twelve mixtures not used in the calibration, with 1, 3 or 6 independent samples of five runs each, served as validation taylor1998a P7, P11, R6, R9.
What the data show
The band-height ratio of a mixture is
I_R = \frac{I_c^{1698}}{I_a^{1680}} = \frac{x_c K_c^{1698} + x_a K_a^{1698}}{x_c K_c^{1680} + x_a K_a^{1680}}
with x the fraction of each form and K a band factor taylor1998a E3. From ten spectra of each pure form the crystalline band contributes 0.052 of its own height at 1680 cm⁻¹ and the amorphous band 0.401 of its height at 1698 cm⁻¹; plotting (x_c-1)(I_R-0.401) against x_c(0.052\,I_R-1) for the calibration mixtures gave a line with correlation coefficient 0.993 and slope 2.72, which fixes
x_c = \frac{I_R - 0.401}{0.859\,I_R + 2.316}
taylor1998a R5, R6, E4, E5. Recalculated with this equation, the calibration mixtures gave slope 1.01, intercept −0.01 and r = 0.9996; the card notes that these are the very mixtures that set the slope, so the independent test is the validation set taylor1998a R7, X5. The validation mixtures gave slope 1.008 and intercept −0.0139, which the authors call "reasonably rugged" taylor1998a R8, C14. Table 1 lists the means: 98.7, 97.7, 96.5 and 93.5% for 99, 98, 97 and 93% crystalline, 96.3% for 96%, 73.6% for 75%, 54.0% for 55%, 21.3% for 25%, 5.9% for 7%, 2.2% for 3%, 1.0% for 2% and 0.9% for 1%, with standard deviations of 0.2–4.0 points taylor1998a R9. All seven compositions at or below 75% crystalline read low, by 0.1 to 3.7 points, and for 25, 7, 3 and 2% crystalline the whole five-run range lay below the actual value, whereas from 93 to 99% the means were within 0.5 points taylor1998a X4, R9. The 2% row (mean 1.0, SD 0.4, range 1.35–0.05) cannot be internally consistent for five runs taylor1998a X3. Ten measurements of each pure form gave a crystallinity SD of 0.2%, so the detection limit (3 SD) is 0.6% and the quantitation limit (10 SD) about 2% (synthesis: 3 × 0.2 = 0.6; 10 × 0.2 = 2); the authors find about 1% detection "reasonable" and the 2% limit too low because the mixture data vary more than the pure-form SD suggests taylor1998a R14, E7, E8, C21. Crystalline indomethacin milled for 5, 15 and 30 min gave spectra like those of the mixtures with more intensity at 1680 cm⁻¹ and Raman-equivalent crystallinities of 85.0, 77.5 and 63.5%; these are equivalents on a two-state calibration, particle size was not evaluated and no second technique was run on the milled samples taylor1998a R15, R16, C19, C20, X9.
| paper | system | method and conditions | result | ids |
|---|---|---|---|---|
| taylor1998a | γ and quench-cooled indomethacin | XRPD, DSC | sharp peaks against a halo; Tg 45 °C; fusion 161 °C, 109 J/g | R1, M1, M2 |
| taylor1998a | pure forms | FT-Raman, 10 spectra each | bands 1698 and 1680 cm⁻¹; band-factor ratios 0.052 and 0.401 | R4, R5 |
| taylor1998a | calibration mixtures, 0–100% | linearized two-band plot, then Eq. 5 | slope 2.72 (r 0.993); recalculated slope 1.01, intercept −0.01, r 0.9996 | R6, R7 |
| taylor1998a | 12 independent mixtures, 1–99% | 1, 3 or 6 samples × 5 runs | slope 1.008, intercept −0.0139 | R8, R9 |
| taylor1998a | low end, 25 to 1% | same | means 21.3, 5.9, 2.2, 1.0, 0.9% | R9 |
| taylor1998a | pure forms, 10 measurements | 3 SD and 10 SD | SD 0.2%; LOD 0.6%; LOQ about 2% | R14, E7, E8 |
| taylor1998a | indomethacin milled 5, 15, 30 min | Raman, Eq. 5, 5 determinations | 85.0, 77.5, 63.5% equivalent | R16 |
| kestur2012 | cited Raman limit | literature value used by the authors | as low as 1%, pure drug without polymer | R17 |
Figure

Why
The authors' explanation (their interpretation): the crystal has a narrow carbonyl band and the glass a broad one, so the crystalline contribution to the 1680 cm⁻¹ position is small (0.052) and the amorphous contribution to the 1698 cm⁻¹ position larger (0.401); the band-factor ratios are assumed to depend only on the scattering parameter of each band ("can be considered") taylor1998a C10, C11, C12, R5. For milled material they note that a physical mixture is a two-state model, each particle wholly amorphous or wholly crystalline, whereas mechanically processed material is more likely partly disordered throughout, so a mixture calibration can only give an equivalent value taylor1998a C17, X9. Not measured: the cause of the low readings at 2–25% crystalline, which the card lists as an open question taylor1998a X4.
Conditions and limits
One compound with two forms that differ in a carbonyl band; powders below 150 µm taylor1998a M1, M2; physical mixtures of two pure forms with no polymer; one composition (55%) for the error tests taylor1998a P8, P9, P10; no measurement of particle-size effects, which the authors warn can change Raman intensity, so standards should match the size distribution of the samples taylor1998a C19, C36, C37. Laser heating was tested only on a 55% mixture, without a sample temperature taylor1998a X10. The method was not tested in a drug–polymer dispersion.
Counterexamples and conflicts
None found in the library for the indomethacin result. In a polymer matrix the picture is harder: for naproxen in HPMCAS the Raman spectra of dispersions are "generally not simple to interpret", chemometrics was needed, and the Raman model built on blends gave an RMSEE of 2.22 against 7.4% for the model built on dispersion standards (F3) kestur2012 C25, R5, R15.
Transfer check
For another drug: (1) record the Raman spectra of the pure crystal and of the glass and look for a band pair, one for each form, and for their overlap; (2) build the calibration from physical mixtures with particle size matched to the samples; (3) validate on independent mixtures, especially below 25%, where this paper's readings ran low, and at the extremes; (4) take the detection limit from the mixtures, not only from the SD of a pure form; (5) average several spectra per sample (F2). A drug whose crystal and glass bands coincide, or whose polymer bands overlap them, is outside the evidence.
History
1998: Taylor and Zografi set the first benchmark in the library, about 1% detection of either form in a powder by FT-Raman, built on their 1997 spectra of the two indomethacin forms taylor1998a C5, C41. 2010: Rumondor and Taylor cite it as the earlier crystallinity quantitation in a pure drug before turning to dispersions rumondor2010b C5; Wanapun and co-workers take its "about 1%" as the limit of XRPD and spectroscopy that SHG should beat wanapun2010 R1, C1. 2012: Kestur and co-workers use Raman as a reference method with its limit "as low as 1%" for pure drug kestur2012 R17, C13.
























