Can PTIR chemically identify and size crystalline drug particles of about 100 nm embedded in a solid polymer film, below the diffraction limit of conventional infrared microscopy?
Yes, for griseofulvin in HPMC: a 90 nm particle was resolved in a 1625 cm⁻¹ PTIR image, spectra of particles of about 100 nm showed the drug bands at a signal-to-noise ratio of 5:1, and sizes from one PTIR image (median 96 nm) resembled light scattering (85 nm). ····
For griseofulvin nanoparticles milled with HPMC and SDS and spin-cast as thin HPMC films on ZnSe, PTIR images at a griseofulvin band located the drug particles, and point spectra separated griseofulvin from HPMC by its bands in 1700–1600 cm⁻¹, down to a 90 nm particle in images and particles of about 100 nm in spectra. ······· The authors present this as the first chemical characterisation of sub-100 nm organic crystals and conclude that PTIR is sensitive to local chemical heterogeneity "to at least the 100 nm scale" in drug–polymer systems. · Stiffness maps from the cantilever's contact resonance showed the particles as stiffer than the matrix, and the authors state that such maps can "greatly" enhance analysis near the resolution limit. ·· Sizes from one thresholded PTIR image agreed in shape with light scattering, which the authors read as "suggesting" that uneven infrared absorptivity does not significantly distort PTIR in this system. ·· The PTIR signal rose with local thickness, and the authors note that resolution depends on absorptivity and thermomechanical properties and "will vary for other samples". ·· Not measured here: a spectrum of the 90 nm particle itself (the abstract says spectra were obtained), the crystallinity of the particles in the film, and the nature of the soft rims around the particles, which are "hypothesized" to be surfactant- and water-rich. ··
01Why this study
In drug–polymer composites such as stent coatings and nanoparticle formulations, polymer choice and microstructure control release and bioavailability, so drug distribution must be characterised at the micro- and nanoscale.
Kamath 2006, ref 1; Sievens-Figueroa 2012, ref 2
Conventional FTIR resolves only 3–30 µm, and AFM shows topography but not composition.
Levenson 2008, ref 11; Dazzi 2012, ref 12 ·
Infrared sSNOM resolves about 20 nm, but its signal is about six times weaker and needs heavy processing to compare with FTIR.
Huth 2012, ref 15; Levin 2005, ref 18 ·
It had mapped polymer blends and living cells, and this group had used it on pharmaceutical blends.
Dazzi 2010, ref 23; Van Eerdenbrugh 2012, refs 8, 31 ·
More detail
The paper cites by number. The introduction builds on these points:
- Why nanoscale chemical mapping matters. Drug–polymer composites, for example drug-eluting stent coatings (Kamath 2006, ref 1) and nanoparticle formulations such as HPMC films and fluidised-bed coated nanocomposites (Sievens-Figueroa 2012, ref 2; Bhakay 2013, ref 3), control release kinetics and bioavailability through polymer choice and composite microstructure. Engineering them needs an understanding of drug structure and distribution in the dosage form (refs 4–7, including Zhu 2010, ref 5), and so methods that chemically characterise formulations unambiguously on the micro- and nanoscale.
- What FTIR and AFM cannot do. FTIR carries rich chemical and structural information and is widely used on drug–polymer composites (Van Eerdenbrugh 2011, ref 4; Van Eerdenbrugh 2012, ref 8), but the optical diffraction limit restricts its spatial resolution to 3–30 µm (refs 9–12). AFM topography and phase contrast hint at nanoscale make-up but cannot describe composition directly. ·
- Near-field optics. Infrared sSNOM, a purely optical technique, has imaged polymer blends, polymer–inorganic systems and nanoparticles in biological materials at about 20 nm (refs 13–17). Its signal is about six times weaker than absorption-based infrared spectroscopy (Levin 2005, ref 18), and relating the scattered light to FTIR spectra needs substantial post-processing, especially for unknown samples (Knoll 1999, ref 19). ·
- PTIR. Photothermal induced resonance uses the larger signal from absorption and gives spectra directly comparable to FTIR at nanoscale resolution; it had assessed polymer blends (refs 8, 24–31) and living cells (refs 20–22, 32, 33).
- How PTIR works. The sample sits on a ZnSe prism that is transparent in the mid-infrared. A tunable OPO nanosecond laser pulse at an absorption band heats the sample, which expands; the AFM cantilever in contact rings, the Fourier transform of its deflection gives its modes, and the maximum mode amplitude versus wavenumber is a local spectrum (Dazzi 2010, ref 23), described as "highly sensitive and quantitative" at the harmonic modes. The contact resonant frequency also shifts with surface stiffness, so a stiffness map can be recorded at the same time (Dazzi 2012, ref 12).
- Earlier PTIR in this group. PTIR had been used on phase separation in a drug–polymer blend (Van Eerdenbrugh 2012, ref 8) and on the miscibility of dextran or maltodextrin with poly(vinylpyrrolidone) (Van Eerdenbrugh 2012, ref 31).
What the paper set out to do. Evaluate PTIR for the chemical and mechanical characterisation of organic drug particles of about 100 nm embedded in solid matrices, using griseofulvin particles in HPMC, and so extend the group's earlier PTIR work to drug formulations; check that PTIR particle sizes agree with light scattering; and record spectra well above noise for particles of about 100, 350 and 800 nm.
02How they approached it
Two griseofulvin nanosuspensions of different size were spin-cast into thin HPMC films: the coarser one tested whether PTIR identifies the drug, the finer one probed the resolution limit, and the PTIR size distribution was checked against light scattering. ··
What was done
GF milled with HPMC and SDS by the standard and the intensified process→d50 by DLS.···
Suspensions diluted in HPMC/SDS solution→spin-cast on ZnSe→films of about 500 and 100 nm.··
Sample 1: height and PTIR image at 1710 cm⁻¹→spectra 1800–1200 cm⁻¹ on a particle and on the matrix.····
Sample 2: height, PTIR at 1625 cm⁻¹ and stiffness images at 10 and 2.5 µm→particles down to 90 nm.·····
Thresholded 1625 cm⁻¹ image→projected areas→equivalent diameters.···
Image-analysis distribution versus DLS of the same suspension.
Spectra 3600–1000 cm⁻¹ on particles of about 100, 350 and 800 nm and on HPMC→S/N and drug-to-matrix signal ratio at 1625 cm⁻¹.··
More detail
What was done
- Suspensions. Sample 1 (10% GF, 2.5% HPMC E15LV, 0.5% w/w SDS) was made by the standard wet stirred media milling process of ref 2. Sample 2 (10% GF, 2.5% HPMC E3, 0.2% w/w SDS) came from an "intensified" process using 100 µm yttrium-stabilized zirconia beads, the HPMC/SDS combination and the low-viscosity HPMC grade, milled for 6 h. ··
- Size by DLS. The suspensions were stirred at 300 rpm for 30 min, diluted 1:19 (sample 1) or 1:30 (sample 2) with water and measured on a Zetasizer Nano-zs: d50 335.7 nm and 85 nm. ·
- Films. 0.5 mL of sample 1 was added to 4 mL of a 2.5% HPMC E15LV / 0.5% SDS solution (called a 1:8 dilution) and 0.05 mL of sample 2 to 2 mL of the same solution (1:40); each was spin-cast on a ZnSe prism at 2000 rpm for 20 s. The tip's drop at the film edge gave average thicknesses of about 500 nm (sample 1) and 100 nm (sample 2). The dry-film drug content is not printed; from the recipes it is roughly 27 and 7.5 wt% (extractor estimate). ···
- PTIR. An Anasys nanoIR AFM with C-450 silicon cantilevers in contact mode recorded the peak-to-peak cantilever oscillation after each OPO laser pulse, normalised by averaged background spectra. Images used the cantilever's first mode (61.0 kHz) at 1710 cm⁻¹ for sample 1 and its third mode (394 kHz) at 1625 cm⁻¹ for sample 2, with pixel spacings of about 4 × 8 nm (2 µm images), 20 × 40 nm (10 µm images) and about 10 nm (2.5 µm images). Point spectra were co-averaged over 128 pulses in 4 cm⁻¹ steps (1800–1200 cm⁻¹, 3 min) or 256 pulses in 6.5 cm⁻¹ steps (3600–1000 cm⁻¹, 6.5 min). The contact resonant frequency gave a stiffness map at the same time. ··
- Image analysis. In MATLAB, the 2.5 µm PTIR image of sample 2 (Fig. 2e) was normalised, split into four signal classes (0.45–1, 0.38–0.45, 0.31–0.38 and 0.2–0.31), and each projected area was converted to the diameter of a circle of equal area; the distribution was compared with DLS on a volume basis. ···
Terms used on this page
- PTIR (AFM-IR): infrared spectroscopy read by an AFM tip. The tip senses the thermal expansion of the sample under a pulsed infrared laser tuned to an absorption band, so the lateral resolution is set by the tip and the sample rather than by the infrared wavelength.
- Diffraction limit: the smallest feature a light microscope can resolve; for conventional infrared microscopy the paper gives 3–30 µm.
- Contact resonance (stiffness map): the frequency at which the cantilever rings while touching the sample; stiffer spots raise it.
- d50: the median particle diameter.
- WSMM: wet stirred media milling, grinding drug crystals with small beads in a stabiliser solution to make a nanosuspension.
- S/N: signal-to-noise ratio of a spectral band.
03Main findings
PTIR picks out griseofulvin agglomerates in the film
In the sample 1 film, bright areas of the 1710 cm⁻¹ image match the agglomerates of the height image, and a spectrum on a particle shows the drug bands at 1710, 1664 and 1625 cm⁻¹, which are absent in the matrix. ···
More detail
The 2 × 2 µm height image of sample 1 shows several agglomerates about 0.6–0.9 µm across (Fig. 1a). Illuminated at 1710 cm⁻¹, a band of the griseofulvin ketone groups (Page 1962, ref 35), the same features light up in the PTIR image while the space between them stays dark (Fig. 1b). The particle spectrum from 1800 to 1200 cm⁻¹ shows the two C=O bands at 1710 and 1664 cm⁻¹ and the C=C band at 1625 cm⁻¹, the strongest of the three; the matrix spectrum has none of them. Below about 1500 cm⁻¹ both spectra carry the same broad bands near 1460 and 1340 cm⁻¹, so only the 1700–1600 cm⁻¹ region tells drug from matrix. The authors take the match between the height and chemical images as confirming that the agglomerates are griseofulvin. ····
The PTIR signal follows film thickness
In the sample 1 image, taller features give a stronger signal and sharper outlines than in the height image, while low regions show little contrast. ···
See also Fig. 1
More detail
Infrared intensity in Fig. 1b generally follows local topography: thicker regions and taller structures are brighter, which the authors read as the known thickness dependence of the PTIR signal (Mayet 2008, ref 22). The tall agglomerates even look sharper and higher in contrast in the PTIR image than in the height image; the authors call this an "unexpected" apparent gain in resolution and explain it by PTIR being more sensitive to thickness than contact-mode topography. The gain is seen only in the high regions; lower regions have lower contrast, "suggesting" that resolution and contrast fall as the height difference between particle and matrix falls. The close match between topography and PTIR also "suggests" that the resolution "may be limited" by the size of the tip, and thickness and thermomechanical variations of the matrix can reduce resolution through thermal artifacts (refs 26, 29, 32, 36). These observations led the authors to test smaller particles in a thinner film. ·····
A 90 nm particle is resolved
In the sample 2 film, a 90 nm griseofulvin particle is distinguishable in both the height map and the 1625 cm⁻¹ PTIR map. ·
More detail
The 10 × 10 µm images of sample 2 (Figs. 2a–c) show many particles, from tens of nanometres, which the authors call "likely" primary particles, to about 1 µm, "likely" agglomerates. In the 1625 cm⁻¹ PTIR images, blue marks the weakly absorbing matrix and pink, yellow and red the griseofulvin particles. In the magnified 2.5 × 2.5 µm images (pixel spacing about 10 nm), a 90 nm particle (solid circle) shows as a small spot of higher signal beside a larger particle in the PTIR map (Fig. 2e); a 100 nm particle (dashed circle) is also marked but not discussed. The authors write that this "demonstrates" that sub-100 nm griseofulvin particles can be chemically characterised by PTIR. The image is at one wavenumber; no spectrum was recorded on this particle. ······
Stiffness maps show the particles as stiffer than HPMC
In the contact-resonance maps of sample 2 the particles stand out as stiffer than the matrix, each ringed by a softer region. ··
See also Fig. 2
More detail
The stiffness images, recorded together with the PTIR images (contact resonance near 394 kHz, colour scale 364–424 kHz), show the particles as distinct regions; the authors describe them as "noticeably stiffer" than the surrounding HPMC and say these maps resolve particles better because the resonance shift does not depend on infrared absorptivity. In the figure the particle regions are speckled mixtures of bright and dark pixels with dark rims, and in the 2.5 µm map the matrix shows a network of lighter lines. The nature of the soft rims "is not clear"; the authors hypothesise surfactant- and water-rich regions formed while the film dried. They conclude that stiffness maps can "greatly" enhance PTIR analysis near the resolution limit. No frequency values were reported. ·····
PTIR sizes resemble light scattering
Equivalent diameters from the thresholded 1625 cm⁻¹ image give a median of 96 nm against 85 nm by DLS, with a broadly similar shape. ·
More detail
The image analysis (Fig. 3b) split the normalised PTIR image into four signal classes and converted each projected area into the diameter of an equal-area circle. Plotted as "vol. %" (Fig. 3a), the image-analysis histogram spans about 36 to 570 nm with a median of 96 nm; the DLS curve of the same suspension spans about 40 to 460 nm, peaks near 90 nm and has a median of 85 nm. The authors call the agreement in general shape "reasonable" and read it as "suggesting" that PTIR represents the particle distribution in spite of the heterogeneous sample and, in the abstract, that PTIR is not significantly affected by uneven infrared absorptivity in this system. The comparison rests on one 2.5 µm image, and the thresholds and the counting of nested signal bands are not explained. In the extractor's reading, every histogram bar is a whole multiple of about 0.76 vol% (1/132 of the total), which fits a count of about 132 particles rather than a volume weighting; weighted by volume, the same counts would have a median of roughly 400 nm. ·······
Spectra of particles of about 100 nm stand above the noise
Over 3600–1000 cm⁻¹, the drug bands in 1700–1600 cm⁻¹ were visible for particles of about 100, 350 and 800 nm, at S/N of 5:1, 9:1 and 15:1 at 1625 cm⁻¹; the drug signal there was 5, 8 and 26 times the HPMC signal. ··
More detail
Spectra were recorded at four points of the sample 2 film: on particles of about 800, 350 and 100 nm and on the matrix (Fig. 4). All four carry bands near 3450, 2900, 1460, 1370 and 1150–1050 cm⁻¹ that the HPMC spectrum also shows; only the particle spectra show the griseofulvin bands near 1710, 1660, 1620 and 1590 cm⁻¹, largest for the 800 nm particle. At 1625 cm⁻¹ the authors give "self-consistent" S/N of 5:1, 9:1 and 15:1 and drug-to-HPMC signal ratios of 5, 8 and 26 for the 100, 350 and 800 nm particles, and conclude that PTIR can chemically characterise local heterogeneity "to at least the 100 nm scale". How the S/N and ratios were computed is not stated, and the plotted spectra have no numerical scale. ·····
04Further observations
- Sample 2 is, to the authors' knowledge, the first wet-milled suspension with a median below 100 nm. ·
- Films were about 500 nm (sample 1) and 100 nm (sample 2) thick.
- Outside 1700–1600 cm⁻¹ the drug spectra carry the HPMC bands. ·
More detail
- A sub-100 nm milled suspension. The intensified milling (100 µm beads, low-viscosity HPMC E3, 0.2% SDS, 6 h) gave a d50 of 85 nm, against 335.7 nm for the standard process; the authors state that, to their knowledge, a median below 100 nm had not been reached by this process before. ··
- Thin films. Sample 1 films averaged about 500 nm and sample 2 films about 100 nm; the lowest heights in the AFM images are referenced to these thicknesses and the highest heights to embedded griseofulvin clusters. ·
- Matrix bands everywhere. In both spectral data sets the HPMC bands (near 1460 and 1340–1370 cm⁻¹, and in Fig. 4 also near 3450, 2900 and 1150–1050 cm⁻¹) appear on and off the particles, and the sample 1 particle spectrum is slightly weaker than the matrix spectrum in that region; drug identification rests on the 1700–1600 cm⁻¹ bands. ·
- Where the spectra were taken. In the Fig. 4 inset, the 800 nm spot is on a large agglomerate, the 350 nm spot on an isolated particle, the 100 nm spot on a small feature next to the agglomerate, and the HPMC spot at the lower right. ·
05How the authors connect the findings
More detail
- PTIR spectra are directly comparable with FTIR, and griseofulvin has bands (C=O at 1710 and 1664 cm⁻¹, C=C at 1625 cm⁻¹; ref 35) where HPMC does not absorb. Imaging at one of them makes the drug particles bright and the matrix dark; the match with topography confirms the identity. ···
- Because the PTIR signal grows with local thickness, tall particles look even sharper than in topography, but low regions lose contrast; the authors infer that resolution and contrast fall as the topographic difference falls and that the tip size "may" set the limit. ···
- They therefore moved to a finer suspension in a thinner film, imaged at 1625 cm⁻¹: a 90 nm particle was distinguishable, which they take to show chemical characterisation below 100 nm and beyond the diffraction limit. Stiffness maps, independent of absorptivity, sharpen the picture further. ···
- To test whether PTIR images give true sizes, they compared a size distribution from one image with DLS; the "reasonable" agreement is read as "suggesting" that inhomogeneous absorptivity does not significantly affect PTIR in this system. ·
- Finally, full spectra of particles of about 100, 350 and 800 nm stand above the noise in 1700–1600 cm⁻¹ (S/N 5:1 to 15:1), which the authors say "indicate" sensitivity to at least the 100 nm scale. ·
What sets the limit. Resolution depends on the absorptivity and thermomechanical properties of the components, so the true resolution will vary for other samples; thickness and thermomechanical variations of the matrix can add thermal artifacts. ·
Conclusion drawn. For materials that differ enough in "electronic and mechanical properties", the method "offers great promise" for nanoparticle and microstructure characterisation of drug delivery systems, and PTIR "can be used to unambiguously" characterise drug formulations at these length scales. ·
06What it means for formulation
- PTIR can chemically characterise drug formulations, such as drug nanoparticles in polymer films, at micro- and nanoscale lengths. ·
- Stiffness maps help near the resolution limit.
- To map a drug in a polymer by PTIR, image at a drug band where the polymer does not absorb; here only 1700–1600 cm⁻¹ qualified.
- Sizes from a PTIR image depend on film thickness and on the chosen thresholds; check them against an independent size method, as done here.
More detail
- As drug delivery moves to micro- and nano-engineered structures, PTIR "can be used to unambiguously" chemically characterise drug formulations at these length scales.
- For materials with sufficient differences in electronic and mechanical properties, the method "offers great promise" for nanoparticle and nano/microstructural characterisation of drug delivery systems.
- Near the resolution limit, contact-resonance stiffness maps can "greatly" enhance the analysis.
- Resolution depends on the absorptivity and thermomechanical properties of the components and will vary for other samples.
- The method suits questions such as whether milled drug nanocrystals stay dispersed or agglomerate once dried into a polymer film or matrix: Figs. 1 and 2 show both single particles and agglomerates in the same films.
- A drug band free of polymer absorption is essential; here only 1700–1600 cm⁻¹ qualified, so drugs whose bands overlap the polymer's will be harder to map.
- Image intensity follows thickness, so a bright area is not simply more drug; sizes or contents taken from PTIR images need an independent check, as the DLS comparison provided here.
- The stiffness contrast was qualitative and the particles' crystallinity was not checked; PTIR and stiffness maps alone do not show that embedded particles are crystalline.
07Open questions
- What are the soft regions around each particle?
- How will resolution change for other drug–polymer systems?
- No spectrum of the 90 nm particle is shown.
- Crystallinity of the particles in the films was not measured.
- The size comparison rests on one image and unexplained thresholds.
More detail
- The soft regions around each particle are not explained; surfactant- and water-rich zones formed on drying are hypothesised but not tested.
- The true resolution will vary with absorptivity and thermomechanical properties, so other drug–polymer pairs need their own tests.
- A point spectrum of the 90 nm particle, which the abstract implies, is not shown; the smallest spectrum is from a particle of about 100 nm.
- Whether the particles are crystalline after milling and in the dried film was not checked by any solid-state method.
- The size distribution comes from one 2.5 µm image with unexplained thresholds; repeat images, other thresholds and particle counts are missing. ·
- Whether the image histogram is weighted by volume, as labelled, or by number, as its bar heights suggest, is unresolved.
- How the S/N and drug-to-matrix ratios were computed is not stated.
- Only one drug and one polymer type were studied, and the two films differ in several factors at once.
08How solid
AI assessment, not a statement made in the paperThe images and spectra directly show griseofulvin particles in HPMC with clear drug bands. But each result rests on one image or one spectrum, the size comparison depends on undisclosed thresholds and on a histogram whose weighting is unclear, crystallinity is assumed, and the abstract's "spectra of 90 nm particles" goes beyond the figures. ······
More detail
- The drug bands at 1710, 1664 and 1625 cm⁻¹ appear on particles and not in the matrix, in both films. ·
- Bright PTIR areas coincide with particles in topography at two bands and two scales. ·
- A 90 nm feature is visible in the PTIR map at a pixel spacing of about 10 nm.
- Spectra of particles of about 100 nm show the drug bands above noise, with a stated S/N of 5:1. ·
- The PTIR and DLS medians (96 and 85 nm) are close.
- The abstract says spectra of 90 nm particles were obtained; only an image at one band is shown for that particle.
- Crystallinity is assumed, not measured.
- The PTIR size distribution depends on threshold and segmentation choices in one image, with no replicate images, and compares a different quantity from DLS. ·
- The image histogram is labelled vol%, but its bar heights are whole multiples of one unit, as a particle count would be; if it is number-weighted, the agreement with the volume-based DLS curve is not like for like.
- The reading that absorptivity does not distort PTIR sizes rests on that one comparison, while the signal clearly follows thickness.
- The S/N and signal ratios lack a stated method and cannot be checked from the figure.
- The two samples differ in many factors at once.
- The general claim of "unambiguous" characterisation outruns one drug–polymer pair.
09Figure guide
Every figure and table of the paper, what it is there for, and what to check on the original. Key figures are shown with the story.
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Fig. 1 (p.9)key figure | Identifies the agglomerates of sample 1 as griseofulvin by matching the 1710 cm⁻¹ image to topography and by the particle spectrum.·· | F1, F2, K1, K7 | Outside 1700–1600 cm⁻¹ the particle and matrix spectra share the HPMC bands. |
| Fig. 2 (p.10)key figure | Shows the sample 2 particle population, a 90 nm particle in the PTIR map and the stiffness contrast.··· | F3, F4, K2, K4 | The 90 nm particle is imaged at one band only; stiffness contrast is qualitative.· |
| Fig. 3 (p.11)key figure | Compares PTIR image-analysis sizes with DLS: d50 96 versus 85 nm.· | F5, K5, K6 | Threshold basis, nested bands and particle count not stated; histogram labelled vol% but bar heights look like counts.·· |
| Fig. 4 (p.12)key figure | Spectra of particles of about 100, 350 and 800 nm against HPMC, with the drug bands in 1700–1600 cm⁻¹.· | F6, K3 | No absorbance scale; S/N method and particle sizing not stated.· |