Can the drug–polymer temperature–composition phase diagram, built from melting point depression, set the lowest hot melt extrusion temperature that avoids residual crystals in an ASD, and how does residence time act together with temperature?
For 50% indomethacin in PVPVA, yes: no extrudate made below the predicted critical temperature of 131 °C was crystal-free, even after 20 min, while at 131 °C a 20 min run and at 141 °C a 10 min run were classed amorphous by all three methods. ··
For indomethacin–PVPVA at 50% drug loading, the critical temperature Tc obtained from DSC melting point depression and the Flory–Huggins equation (131 °C, about 30 °C below the drug's melting point) marked the lowest product melt temperature that gave crystal-free extrudates; below it crystallinity persisted at every residence time tested, which the authors read as the loading exceeding the crystalline solubility ("suggesting"). ··· At and above Tc the outcome depended on residence time, and where the amorphous zone begins depended on the sensitivity of the detection method, with polarized light microscopy the most and DSC the least sensitive. ··· From this the authors build a process design space of three regimes (melting above the drug's melting point, dissolution between Tc and the melting point, suspension below Tc) and conclude that phase diagrams "provide a rational basis" for setting the minimum HME temperature. ·· The scope is one drug, one polymer, one loading, one drug lot and one small recirculating extruder, and the kinetic explanations offered (local heating in the extruder, large drug particles, small defective crystals) were proposed but not measured. ···
01Why this study
Many HME processes run below the drug's melting point to limit thermal degradation, which brings a risk of crystals that do not fully dissolve.
Chokshi 2005, ref 10; Haser 2017b, ref 23 ·
They forfeit the solubility advantage and can seed crystallization on storage and desupersaturation in solution.
Murdande 2010, ref 46; Purohit 2018, ref 54; Que 2018, ref 56
It had been put forward for choosing HME temperatures, but earlier tests used systems with little melting point depression.
DiNunzio 2012, ref 14; Tian 2013, ref 70; Li 2016, ref 38 ·
Only screw configuration and drug particle size reduction had been studied.
Li 2015, ref 37; Liu 2012, ref 40
More detail
The paper cites by author and year; "ref N" below is the entry's position in the printed, unnumbered reference list (78 entries).
What was already known.
- Why HME, and why it runs cool. Spray drying and HME are the two leading commercial ASD processes; HME is solvent-free, continuous and scalable but suits thermally stable systems. (Sandhu 2014, ref 60; Repka 2018, ref 57) Avoiding thermal degradation and avoiding residual crystals are two critical quality attributes of hot-melt-extruded ASDs, and lower temperatures help the first at the expense of the second. (Boersen 2015, ref 7; Evans 2018, ref 15; Vigh 2014, ref 73) Processing below the drug's melting point by exploiting melting point depression is widely documented. (Chokshi 2005, ref 10; DiNunzio 2010, ref 12; Guo 2014, ref 18; Haser 2017b, ref 23; Huang 2017, ref 26)
- What residual crystals do. Residual crystals lose the amorphous solubility advantage (Murdande 2010, ref 46), can accelerate crystallization on storage (Ivanisevic 2010, ref 28) and cause desupersaturation in solution by secondary nucleation or growth (Frawley 2012, ref 16; Ilevbare 2012, ref 27; Purohit 2018, ref 54; Que 2018, ref 56; Sun 2016, ref 65), so the process should give a fully amorphous product (Crowley 2007, ref 11).
- Melting point depression in drug–polymer blends. A miscible polymer lowers the drug's chemical potential and so its melting point; an immiscible one does not. Flory–Huggins theory describes this and has been used to predict ASD phase behaviour and stability. (Marsac 2006, ref 42; Marsac 2009, ref 41; Tao 2009, ref 67; Tian 2013, ref 70; Knopp 2015, ref 30) A negative χ adds depression beyond the combinatorial entropy, and χ can depend on temperature, chain length and composition. (Anderson 2017, ref 3; Zhao 2011, ref 78) ·
- Solubility from two directions. In a miscible system the crystalline solubility measured by different methods is taken as thermodynamically equivalent: the DSC method heats a fixed composition until the crystals dissolve, while extrusion approaches the same equilibrium isothermally from an undersaturated state. (Sun 2010, ref 66)
- The phase diagram for HME. It had been proposed as a way to identify the solubility line and suitable HME temperatures (Boersen 2015, ref 7; Brown 2014, ref 8; DiNunzio 2012, ref 14), and some studies found residual crystals in samples processed below the solubility line (Keen 2014, ref 29; Li 2016, ref 38; Tian 2013, ref 70). Those systems showed little melting point depression, so whether a large depression can be used to process considerably lower without residual crystals "remains an open question". ·
- Mitigation had been mechanical. Strategies against residual crystallinity had been limited to screw configuration and drug particle size. (Li 2015, ref 37; Liu 2012, ref 40)
What the paper set out to do. Show that the temperature–composition phase diagram can guide the HME design space. The authors "hypothesize" that a system with substantial melting point depression can be processed considerably below the melting point and still give an amorphous extrudate, provided the kinetics of crystal dissolution are taken into account; IDM and PVPVA, the most common HME polymer, were chosen as models. ·
02How they approached it
One drug–polymer pair with a large melting point depression, at one loading (50% DL) chosen so that extrusion is possible above, at and below Tc; temperature and residence time were varied, and crystallinity was read by three methods of different sensitivity. ···
What was done
Cryomilled mixtures, 40–90% DL→DSC at 0.5–10 °C/min→melting point offset extrapolated to 0 °C/min = Tc.···
Flory–Huggins melting point depression→χ = −1.97 from a linear fit→predicted solubility line; Gordon–Taylor Tg line.···
50% DL premix→extrusion at 117–161 °C and 2–20 min residence time→milled and sieved extrudates.·
XRPD→% crystallinity.·
PLM→birefringence.·
Modulated DSC→crystal dissolution endotherm.·
HME 117-2 powder on a hot stage at 121–161 °C, no mixing→time to loss of birefringence.·
Outcomes plotted against Tc and residence time→process operating design space (Fig. 8) and three-regime scheme.·
More detail
What was done
- Phase diagram. IDM:PVPVA physical mixtures at every 10% DL from 40% to 90% were cryomilled under liquid nitrogen in triplicate. DSC heated 3–5 mg from 25 to 180 °C at six rates (0.5, 1, 2, 3, 5 and 10 °C/min), and the melting point offset temperature, where the last crystal has dissolved or melted, was read. Because the offset depends nonlinearly on heating rate, a second-order polynomial was fitted and extrapolated to 0 °C/min; this intercept is the equilibrium critical temperature Tc of each composition. The second heating gave the onset dry Tg. ····
- Model. χ was the slope of the linearized Flory–Huggins equation fitted through 90/10 to 50/50 (40/60 excluded for high variability), with the drug molecular volume as lattice volume and volume fractions from true densities. The fitted χ then predicted Tc over the whole composition range, and Gordon–Taylor predicted Tg. ····
- Extrusion. A 1:1 premix (200 g, tumble blended; IDM sieved first) was extruded in 10 g batches on a 5 mL co-rotating micro-extruder at 20 rpm. Product melt temperatures of 117, 121, 126, 131, 134, 138, 141 and 161 °C (± 1 °C, set temperatures 4–5 °C higher) were combined with residence times of 2 min (continuous mode) or 5, 10 and 20 min (melt recirculated before extruding), 15 runs in all (Table II). Extrudates were cryomilled and sieved to 100–250 µm and <100 µm. ·
- Crystallinity. XRPD quantified crystalline IDM against a calibration from crystalline IDM mixed into SE5050 (R² = 0.985; LOD about 0.4%, LOQ about 1%). PLM looked for birefringence in powder under mineral oil. Modulated DSC looked for a crystal dissolution endotherm on heating. ··
- Hot stage. Since a physical mixture gave too little contact for heat transfer, the most crystalline extrudate (117-2, <100 µm) was heated at 100 °C/min to 121–161 °C and held up to 24 h without mixing, timing the loss of birefringence (n = 3). ·
Key equations
The drug's melting point Tm falls to Tc in the mixture by an entropy term set by the drug volume fraction φ and the polymer-to-drug volume ratio m, plus an interaction term in χ; with χ = −1.97 it predicts every Tc of Table III.·
Plotting the left side A against B = (1 − φ)² for the measured Tc gives χ as the slope (−1.97, R² = 0.9895).·
The blend Tg from the weight fractions w, with K from the true densities ρ and Tgs; it gives the formulation Tg line of the phase diagram.·
Used in words only: crystals dissolve faster with a larger diffusion coefficient D (higher temperature, lower viscosity), a larger surface area A (smaller particles) and a thinner boundary layer h (more shear).·
Terms used on this page
- Melting point offset temperature: the end of the melting or dissolution endotherm on a DSC scan, where the last crystal disappears.
- Critical temperature Tc: here, the depressed melting (solubility) temperature of the drug at a given composition; above it the polymer can dissolve all the drug crystals at equilibrium. It is not an upper or lower critical solution temperature.
- Solubility line: Tc plotted against composition.
- Tmin: the lowest temperature at which the polymer melt is fluid enough to process; here 117 °C.
- Residence time: here, the time to the first appearance of extrudate.
- Melting, dissolution and suspension regimes: extrusion above Tm, between Tc and Tm, and below Tc.
03Main findings
PVPVA lowers indomethacin's melting point by about 30 °C at 50% loading
The equilibrium Tc fell from 160.64 °C for pure IDM to 132.3 ± 0.8 °C at 50% DL; one χ of −1.97 reproduced the measured Tc from 50 to 90% DL (predicted 131.0 °C at 50%). ···
More detail
Every mixture showed melting point depression, which the authors take as "confirming" miscibility at elevated temperatures. ·· The extrapolated Tc were 159.9 ± 0.3, 157.2 ± 0.4, 151 ± 3, 141 ± 3 and 132.3 ± 0.8 °C for 90/10 to 50/50, against predicted 159.4, 155.6, 149.6, 141.4 and 131.0 °C; the depression grows steeply once polymer exceeds about 30%. ·· The offset temperature rose with DSC heating rate for every composition, for 50/50 from about 133 °C at 0.5 °C/min to about 146 °C at 10 °C/min, so rate extrapolation matters. At 40% DL the replicates scattered widely (129 ± 6 °C against a predicted 118.5 °C), which the authors attribute to viscosity, and this point was left out of the fit. · The fitted χ = −1.97 (R² = 0.9895) lies within the range reported for the same system elsewhere (−0.64 to −4.5); differences "can be attributed" to preparation and DSC method. ··· Dry Tg values agreed with Gordon–Taylor predictions (72.2 ± 0.5 against 72.9 °C at 50/50). · The authors use Tc = 131 °C ± 2 °C as the lower processing bound for the 50% blend; the experimental value is 132.3 °C. ·
Below Tc no extrudate was crystal-free
Extrudates made at 117–126 °C held about 7–26% crystalline drug after 2 min and still about 1.5–1.8%, above the 1% LOQ, after 10–20 min. ·
More detail
At 2 min residence time, XRPD crystallinity was about 26% at 117 °C, 16% at 121 °C and 7% at 126 °C, and these extrudates were opaque or very cloudy. ·· Longer runs lowered it but never below the LOQ: about 1.5% for 126-10 and 1.8% for 121-20, which still looked cloudy and, for 121-20, carried visible crystals. · PLM showed dense birefringence at 121 °C after 2 and 20 min, and DSC still detected a dissolution endotherm in the 2 min samples at 117–126 °C. · The authors read the persistent crystallinity as "suggesting" that the 50% loading exceeds the crystalline solubility at these temperatures, and the lower-than-expected values after long times as possibly due to local heating above the measured melt temperature ("may be a result of"). ·
At and above Tc, residence time decides
At 131 °C crystallinity fell from about 2.8% at 2 min to about 0.9% at 5 min and to about 0 by XRPD at 10 min; only the 20 min run passed all three methods. At 141 °C, 10 min sufficed; at 161 °C, 2 min. ··
More detail
At 2 min, crystallinity fell steadily with temperature above Tc: about 1.8% at 134 °C, 0.7% at 138 °C, 0.2% at 141 °C and 0 at 161 °C. ··· At 10 min the 134 and 141 °C runs were at about 0.1%. · The authors summarize that longer residence time and/or higher temperature reduce residual crystallinity ("clearly demonstrates"), and that at 131 °C 20 min was required for a crystal-free sample and at 141 °C only 10 min. · The tested grid limits these statements: no 141 °C run between 2 and 10 min was made, and 131-10 was already at about 0% by XRPD. In Fig. 8 the zone "amorphous by all techniques" is bounded by a line the authors drew from about 148 °C at 2 min down to 131 °C at 20 min. The authors present this as the proof that melting point depression can be used to process about 30 °C below the drug's melting point ("convincingly demonstrating").
Where "amorphous" begins depends on the detection method
PLM showed birefringence in samples that XRPD called amorphous, and DSC detected crystals only in the four 2 min samples at or below 131 °C. ····
More detail
PLM was the most sensitive: at 2 min birefringence rose sharply as melt temperature fell, and low levels remained in 141-2, 141-10, 131-10 and 131-20, which XRPD called amorphous; in the long-residence samples it was diffuse, which the authors read as very small, possibly defective, well-distributed crystals ("suggesting"). ··· DSC was the least sensitive: a dissolution endotherm above about 1.5 J/g was consistently seen only in 131-2, 126-2, 121-2 and 117-2, because crystals can dissolve into the melt during the DSC scan itself. · Extrudate appearance was a weak guide: 141-2 and 131-10 looked clear yet had visible crystals. · In Fig. 8 the three zone boundaries (DSC amorphous, X-ray and DSC amorphous, amorphous by all techniques) therefore sit at different places in the temperature–time plane, and the authors conclude that the boundary "depends on the analytical approach". ·· The Fig. 8 classes do not fully match the text: PLM birefringence is noted for 141-10 and 131-20, yet both are classed amorphous by all techniques. ·
Without mixing, crystals near Tc take hours to dissolve
On a hot stage, crystals in 117-2 powder disappeared in under 30 s at 161 °C, in about 2 h at 131 °C, about 8 h at 126 °C and about 20 h at 121 °C. ·
More detail
The times to complete loss of birefringence were about 0.03–0.06 h at 146–151 °C, 0.3 h at 138–141 °C, 0.9 h at 134 °C and 1.9 h at 131 °C, then 7.8 h at 126 °C and 20.2 h at 121 °C, with wide scatter below Tc. Between Tc and Tm dissolution was slower than melting, "as a result of" lower thermal input, higher viscosity and no mixing, and the long times compared with extrusion residence times "emphasize" the role of mixing. · At 121 °C crystals remained after 8 h, which the authors read as a thermodynamic rather than kinetic limit ("suggesting"). · Microscopy implies a lower Tc than DSC, which "could be due to" degradation during long holds or crystals below about 600 nm going undetected; the authors call the data "broadly consistent" with the phase diagram and say Tc = 131 °C is confirmed for holds under 2 h. ·
04Further observations
- The 40% DL blend could not be measured reliably by DSC (129 ± 6 °C against a predicted 118.5 °C). ·
- Dry Tg followed the Gordon–Taylor line from 43.7 °C for IDM to 104.2 °C for PVPVA. ·
- The lowest melt temperature that could be extruded was 117 °C.
- The IDM lot contained many particles over 150 µm despite a D50 of about 22 µm.
More detail
- 40% DL is viscosity-limited. Replicates at 40/60 scattered by about ±6 °C at the slowest rates and the mean Tc lay above the predicted line; the authors left it out of the χ fit and attribute the deviation to viscosity. ··
- Tg. Experimental onset Tg rose from 47.0 °C at 90/10 to 77.6 °C at 40/60, close to the Gordon–Taylor predictions (49.4 to 79.0 °C). ··
- Tmin. A minimum processing temperature of 117 °C was observed with this extruder and formulation, which the authors attribute to the drop in viscosity as IDM dissolves into and plasticizes PVPVA; the Fig. 2 caption places it 10–15 °C above the PVPVA Tg. · They state that below 50% DL this Tmin, not Tc, would be the lower bound; the predicted Tc at 40% DL (118.5 °C) still lies just above 117 °C. ··
- Large particles. Many IDM particles were over 150 µm (data not shown), and the authors think these "are likely the primary reason" for the trace birefringence after long residence times. ·
- Appearance. Extrudate appearance ranged from opaque (117-2, 121-2) through cloudy to clear, but "clear" did not exclude visible crystals.
05How the authors connect the findings
More detail
- Melting point depression arises because a miscible polymer lowers the drug's chemical potential; a negative χ adds to the entropic effect. For IDM–PVPVA, with favourable specific interactions, the depression is about 30 °C at 50% DL. Tc is then the minimum theoretical product melt temperature at which the crystals can fully dissolve, recognizing that the measured temperature may differ from what the melt experiences. ···
- Building on two earlier classification schemes, the authors map the design space into regimes bounded by the drug's melting point, the formulation Tc and the polymer Tmin, with thermal degradation above and an inaccessible zone below Tmin. Residence time is the kinetic axis; higher temperatures and longer residence times raise the degradation risk, lower and shorter ones the crystallinity risk. ·
Melting regime. Above Tm (161 °C for γ-IDM) the drug melts, so even minimal mechanical input and time give a homogeneous melt, with "no risk of residual crystallinity, unless the drug recrystallizes during cooling".
Dissolution regime. Between Tc and Tm (131–161 °C for this blend) the polymer softens around suspended crystals; a dissolution boundary layer and a heat-transfer boundary layer form at each crystal and are thinned by mixing, and the crystals shrink until molecularly dispersed. In Noyes–Whitney terms, higher temperature and plasticization by the dissolving drug raise the diffusion coefficient, and higher screw speed and shear thin the boundary layer; large particles dissolve slowly. With insufficient mixing or residence time, crystals "will be entrapped". ···
Suspension regime. Below Tc (below 131 °C here) the same sequence runs more slowly and ends with residual crystals; "a completely amorphous dispersion cannot be achieved under any kinetic conditions".
What sets the switch point. Thermodynamics sets where the regimes lie (Tm and Tc); particle size, screw configuration and residence time set how far into the dissolution regime the line between crystalline and amorphous product moves, the authors predict, a smaller particle size shifting it to shorter times. ··
Conclusion drawn. The authors conclude that the phase diagram "provides a rational framework" for preventing residual crystals and that melting point depression "can be effectively utilized as a risk-based process design strategy", in the spirit of the ICH Q8(R2) design space. ·
06What it means for formulation
- Set the minimum product melt temperature at the composition's Tc from the phase diagram, and allow enough residence time and mixing above it. ·
- Control the drug's particle size; lots with larger particles may leave crystals.
- Define the amorphous boundary with a stated detection method and link crystallinity limits to product performance. ·
- For a heat-sensitive drug with a large melting point depression, the window between Tc and Tm is usable, but near Tc the required residence time grows quickly; a margin above Tc buys time.
- An X-ray amorphous or clear extrudate can still carry seeds visible by PLM.
More detail
- Tc is the theoretical minimum processing temperature for a composition; processing at Tc also needs sufficient time and appropriate mixing, and the measured melt temperature may not equal the local temperature. ·
- Where the solubility line drops below the polymer's Tmin (here below 50% DL, according to the authors), Tmin within the equipment's viscosity limits sets the lower bound. ·
- Particle size control over the starting drug is "critical", and a robust screw configuration and vigorous mixing help. ·
- Zone boundaries could be set by XRPD thresholds (<1%, <2%, <5%) through modelling or design of experiments, together with evidence that such levels do not affect performance.
- Residual crystals "may" compromise stability and dissolution, so their consequences should be understood before specifications are set.
- In this system, extruding 10 °C above Tc halved the time needed for a product amorphous by all methods (20 min at 131 °C, 10 min at 141 °C), and 3 °C above Tc already gave an X-ray amorphous product in 10 min (134 °C); in a continuous extruder with residence times of a few minutes, a margin above Tc matters more than the exact Tc.
- Clear appearance and X-ray amorphousness did not guarantee the absence of crystals; PLM was the method that separated "trace" from "none" here.
- The 50% loading, the recirculating micro-extruder and the long residence times mean the residence-time numbers do not transfer directly to a production twin-screw extruder; the temperature bound (Tc) is the more transferable result.
07Open questions
- What crystallinity level can be tolerated without affecting product performance? ·
- How do particle size and screw configuration move the boundary between crystalline and amorphous product?
- Only one composition, one drug lot and single runs per condition were tested.
- Whether the trace crystals left near Tc matter for stability or dissolution was not tested.
More detail
- Set residual crystallinity limits and confirm by performance testing that such levels are harmless. ·
- Smaller particles should shift the transition line to shorter residence times and larger ones to longer; changes in screw configuration or other parameters also move it.
- Local heating by viscous dissipation may be significant but was not detected with this extruder and thermocouple. ·
- Loadings other than 50% DL were not extruded, so the predicted Tc at other compositions and the switch to Tmin were not tested by extrusion.
- The number of runs per condition and of XRPD measurements per sample is not given, and Fig. 3 has no error bars.
- Melt viscosity, local temperature and thermal degradation were not measured, although they carry several explanations. ··
- The stability and dissolution of extrudates with trace crystals were not studied.
08How solid
AI assessment, not a statement made in the paperThe phase diagram reproduces from its printed inputs and the central contrast (crystals at every residence time below Tc, none by XRPD after 10 min at Tc and above) is consistent across three methods. But each condition is a single run at one loading on a small recirculating extruder, and the required times are set by the tested grid. ···
More detail
- Equation 2 with the printed χ, densities, ΔH and Tm reproduces every predicted Tc of Table III, and Gordon–Taylor reproduces every predicted Tg. ·
- All five extrudates made below 131 °C stayed above the 1% LOQ by XRPD, including the 10 and 20 min runs.
- XRPD, PLM and DSC rank the samples in the same order of crystallinity. ···
- Hot-stage times rise steeply as temperature falls through Tc, in line with the phase diagram.
- Each extrusion condition seems to be a single run, with no error bars on crystallinity.
- The stated times (20 min at 131 °C, 10 min at 141 °C) are the first tested conditions that passed every method, not measured minima.
- The Tc used (131 °C) is the predicted value; the experimental value is 132.3 ± 0.8 °C, so the "at Tc" runs lie on or just below the boundary.
- The PLM text and the Fig. 8 classes disagree for 141-10 and 131-20, and the X-ray criterion in Fig. 8 is not stated. ·
- The hot-stage test used a partly dissolved extrudate, and its agreement with Tc depends on a 2 h window. ·
- The Tmin of 117 °C is an observation for this blend and extruder, and the switch to Tmin below 50% DL does not match the predicted solubility line. ·
- The χ fit form (with intercept) differs from the printed A = χB.
09Figure guide
Every figure and table of the paper, what it is there for, and what to check on the original. Key figures are shown with the story.
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Table I (p.7) | Gives the inputs of the model: molecular weight, Tm, ΔH, Tg, density, molecular volume and particle size of IDM and PVPVA.· | 0.2 | n for the PVPVA Tg is 3 in the table and 6 in the methods. |
| Table II (p.12) | Lists the 15 extrusion runs: set and melt temperature, residence time and appearance.· | F2, F3 | Runs per condition not stated. |
| Fig. 1 (p.16)key figure | Builds the melting point depression data: thermograms, offset versus heating rate and the χ fit.·· | F1, K1 | Fig. 1a arrows differ from Fig. 1b at 10 °C/min; χ reproduces only with an intercept.· |
| Table III (p.18) | Experimental and predicted Tc and Tg for every composition: the numbers behind the phase diagram. | F1, K1 | 131 °C used as Tc is the predicted value; measured 132.3 ± 0.8 °C. |
| Fig. 2 (p.19)key figure | The phase diagram with solubility line, Tg line, Tm, PVPVA Tg and Tmin. | F1, K1, K6 | The solubility line crosses Tmin near 39% DL, not 50%. |
| Fig. 3 (p.20)key figure | The main result: XRPD crystallinity against melt temperature for 2–20 min residence times. | F2, F3, K2, K3 | No error bars; single runs. |
| Fig. 4 (p.21)key figure | PLM evidence that trace crystals survive where XRPD sees none. | F4, K4 | Frames C and F show birefringence but are classed amorphous in Fig. 8. |
| Fig. 5 (p.24)key figure | Hot-stage dissolution times and micrographs without mixing.· | F5, K5 | Sample was the partly dissolved 117-2 extrudate. |
| Fig. 6 (p.26)key figure | Schematic of the HME design space on the phase diagram and against residence time.· | 0.5 | A schematic, not data. |
| Fig. 7 (p.30)key figure | Schematic of the melting, dissolution and suspension regimes.··· | 0.5 | A schematic, not data. |
| Fig. 8 (p.35)key figure | The experimental design space: each run classed by detection method, with zone lines.· | F3, F4, K3, K4 | X-ray criterion unstated; required times set by the tested grid.· |
| Graphical abstract (p.46) | Schematic summary of the design space and the two outcomes. | A schematic, not data. | |
| Figs. S1–S4 (SI, cited p.11–22) | Extruder schematic, extrudate photographs, XRPD diffractograms and DSC curves; SI not supplied.· |