How does polymer hydrophobicity change the release of drug and polymer from an ASD as drug loading rises, and where is congruent release lost?
For felodipine, PVP and HPMC lost congruent release above 10% DL and PVPVA above 15% DL; one step higher, drug release from PVP and PVPVA fell about 200-fold. HPMCAS and EUDS stayed congruent up to 50% DL, the highest tested, but at 10% DL they released drug 3-24 times more slowly than PVP and PVPVA; at 20-30% DL HPMCAS released drug about 100-250 times faster than PVPVA. ····
The authors conclude that drug-loading-dependent release falls into two patterns that "appear to depend" on polymer hydrophobicity: hydrophilic, non-ionizing polymers give rapid, polymer-controlled release at low loading and markedly reduced drug release above the LoC, while hydrophobic polymers that must ionize to dissolve give more consistent release, with some decline of both components at high loading. ··· Water-induced AAPS is "likely" the cause of the cliff for PVP, PVPVA and HPMC, and the lower water uptake of HPMCAS and EUDS "conceivably" explains why they show no LoC up to 50% DL. · In HPMCAS at 40% DL a more lipophilic drug slowed both drug and polymer release, and the polymers that hydrogen-bond most strongly to felodipine (PVP, PVPVA) had low, not high, LoCs, so the role of interactions "if any" needs further work. ·· From this the authors derive a "trade-off": hydrophilic polymers "may be a better choice" below the LoC, hydrophobic polymers at higher loading. The scope is one drug (felodipine; two analogues at one loading in HPMCAS) in non-disintegrating compacts at 37 °C; phase separation inside the dissolving tablets was not measured, as it rests on 30% DL films held at 97% RH and on surface imaging of 30% DL tablets. ···
01Why this study
A 2-20-fold solubility gain gives a similar dissolution-rate gain, likely too little for very insoluble drugs.
Taylor and Zhang 2016, ref 42; Noyes and Whitney 1897, ref 27 ·
At low loading drug and polymer leave together at the polymer's rate, and concentrations above the amorphous solubility give drug-rich nanodroplets that act as a reservoir.
Higuchi 1965, ref 11; Indulkar 2016, ref 12 ·
Congruent release had been seen only up to 25% DL, mostly with PVPVA, whose LoC ranged from 5% (ledipasvir) to 25% (ritonavir).
Loading-dependent failure was also seen with other polymers, but no link between polymer properties and LoC had been found.
More detail
The paper cites by author and year; reference numbers here are positions in the printed, alphabetical reference list (pp.14-15).
What was already known. The introduction and discussion build on these points:
- The amorphous advantage is modest. An amorphous drug is typically 2-20 times more soluble than its crystal, and by the Noyes-Whitney equation its dissolution rate gains about as much; the highest concentration it can reach is the amorphous solubility, where passive membrane transport is maximal. For exceptionally insoluble drugs this gain is "likely still insufficient". (Taylor and Zhang 2016, ref 42; Noyes and Whitney 1897, ref 27; Raina 2014, ref 32) ··
- Two-component dissolution theory. Higuchi and co-workers showed that in a dispersion each component's dissolution depends on composition. At high loading both components first dissolve independently, the faster polymer leaves a drug-rich barrier layer, and that layer then controls release; congruent release is possible only at a critical mixture ratio (Eq. 4). At low loading there is too little drug for an intact layer, so release is controlled by polymer dissolution and drug and polymer leave at the same rate (Eq. 2). Corrigan noted the limits of these models for non-disintegrating systems with very different solubilities. (Higuchi 1965, ref 11; Simonelli 1969, ref 38; Corrigan 1985, ref 5) ···
- Why congruent release matters. Polymers usually dissolve orders of magnitude faster than drugs, so congruent release is fast and complete; it can also exceed the amorphous solubility, which triggers LLPS into drug-rich nano-sized aggregates. These act as a reservoir that sustains maximum flux in membrane-transport studies, and in some in vivo studies they raised bioavailability. (Indulkar 2016, ref 12; Wilson 2018, ref 49; Stewart 2017, ref 39; Kesisoglou 2019, ref 15) ·
- The LoC. Congruent release had been seen only at low loadings (≤25% w/w), mostly with PVPVA. The loading at which release switches to incongruent, with a steep drop in drug release, is the limit of congruency; for PVPVA it ranged from 5% DL (ledipasvir) to 25% DL (ritonavir) and is "thought to depend" on drug properties and drug-polymer interactions. A low LoC is a problem for high-dose drugs and pill size. (Indulkar 2019, ref 13; Saboo 2019, ref 36; Bhardwaj 2018, ref 1; Que 2019, ref 31) ·
- Other polymers. PVPVA is common in marketed ASDs, but other polymers are used; poor release at high loading has also been seen with them, without any established link between polymer properties and LoC. (McKelvey and Kesisoglou 2019, ref 23; Newman 2017, ref 26; Davis 2017, ref 7; Purohit and Taylor 2017, ref 30; Jackson 2016, ref 14)
- Water-induced phase separation. Water can make drug and polymer separate (AAPS) during hydration, which is expected to harm dissolution; whether it happens depends on loading, polymer, the relative affinity of drug and polymer for water and how much water is absorbed, and its kinetics compete with dissolution. The group had shown that AAPS turns a congruently releasing ASD into an incongruent one. Strong drug-polymer interactions "may" resist AAPS. (Purohit and Taylor 2015, ref 29; Rumondor 2009, ref 34; Rumondor 2011, ref 35; Marsac 2010, ref 22; Saboo 2019, ref 36) ··
- Drug effects on HPMCAS release. Drug had been reported to slow HPMCAS dissolution, attributed to binding and swelling, strong interactions or greater ASD hydrophobicity; at low loading, an earlier study found no correlation of release with drug log P. (Chen 2016, ref 3; Corrigan 1985, ref 5; Merkel 1983, ref 24; Saboo 2019, ref 36) ·
What the paper set out to do. Probe the release mechanism of felodipine ASDs made with five polymers of different hydrophobicity and chemistry across drug loadings, find the role of polymer hydrophobicity, and, with two analogues at 40% DL in HPMCAS, test whether drug hydrophobicity also matters. ··
02How they approached it
One poorly soluble drug, felodipine (crystalline solubility 1.3 µg/mL), in five polymers spanning hydrophobicity; drug and polymer release measured separately from constant-area compacts at rising loading; tablet surfaces, humid films and IR then probe why release changes. ···
What was done
Neat polymers→water sorption 5-95% RH and buffer contact angle→hydrophobicity rank.···
Felodipine crystalline and amorphous solubility, pH 6.8, 37 °C.··
100 mg compacts in Wood's apparatus, 100 mL buffer, 37 °C→drug and polymer by HPLC→normalized rates and LoC per polymer.···
Nil, Fel, Cil at 40% DL in HPMCAS→rates versus log P.·
30% DL tablets after 10 min→micro-CT, SEM, EDX chlorine.···
30% DL films, 24 h at 97% RH→confocal imaging with prodan.·
30% DL films→FTIR of the felodipine NH band.·
Higuchi critical mixture ratio for Fel-PVPVA.·
LoC against neat-polymer dissolution rate, and drug rate against loading for PVPVA, HPMCAS and EUDS (Figs. 14, 15).··
More detail
What was done
- Hydrophobicity ranking. Water sorption isotherms of the neat polymers and amorphous felodipine were run once each at 37 °C from 5 to 95% RH in 10% steps. Buffer contact angles were measured on spin-coated films of each polymer (triplicate films), with pH 7.4 buffer for EUDS. ·
- Solubility. Crystalline felodipine was equilibrated 48 h at 37 °C in pH 6.8 buffer with and without 1000 µg/mL of each polymer; the amorphous solubility was taken from a supersaturated solution with 100 µg/mL HPMC after ultracentrifugation. ·
- ASDs. Solutions in 1:1 methanol:dichloromethane were rotary-evaporated, dried, cryo-milled and sieved to 106-250 µm; fresh ASDs were amorphous by PXRD with one Tg by DSC. Loadings were 5, 10, 15, 20 and 30% for PVP, PVPVA and HPMC, and 10-50% in 10% steps for HPMCAS and EUDS. ··
- Release. 100 mg of powder was compressed into an 8 mm die (about 0.5 cm² exposed), rotated at 100 rpm in 100 mL of 100 mM phosphate buffer (pH 6.8; pH 7.4 for EUDS) at 37 °C under non-sink conditions, and sampled over 1 h (longer for some high-loading HPMCAS and EUDS compacts, X9). Drug was assayed by HPLC-UV, PVP and PVPVA by SEC-UV, EUDS by SEC-UV and HPMC and HPMCAS by HPLC-ELSD. Each rate was the slope of the release curve normalized by area and by the component's weight fraction (Eq. 3), n = 3. ···
- Drug hydrophobicity. Nilvadipine, felodipine and cilnidipine (log P 4.06, 4.46, 5.40) were compared at 40% DL in HPMCAS; their water uptake at 100% RH was extrapolated from vapour sorption isotherms. ··
- Surfaces and films. At 30% DL, tablets taken out after 10 min were dried and examined by micro-CT, SEM and EDX (chlorine marks felodipine). Films with 0.2 wt% prodan, which collects in drug-rich domains, were imaged by confocal microscopy before and after 24 h at 97% RH. Films on KRS-5 were measured by transmission FTIR. ····
- Theory check. The Higuchi critical mixture ratio was estimated for Fel-PVPVA from the amorphous solubility, a literature PVPVA solubility and a Stokes-Einstein diffusion-coefficient ratio of 10. ··
Key equations
When release is polymer-controlled, drug comes out at the polymer's rate scaled by the drug:polymer weight ratio N; after normalization by weight fraction the two rates are equal, which is how congruency is read throughout.
The slope k of concentration against time (mg/mL per min, without the origin), times the medium volume V (100 mL), divided by the exposed area S (0.5 cm²) and the component's weight fraction N, gives each component's rate per unit area as if it were the pure material.
In Higuchi's diffusion model only this ratio of weight fractions N, set by diffusion coefficients D and solubilities C_s, releases both components congruently; for Fel-PVPVA it is tiny, so the model cannot explain congruent release up to 10-15% DL. The SI prints 1.7 x 10⁻⁶; its own inputs give 1.7 x 10⁻³.···
Terms used on this page
- Congruent release: drug and polymer leave the dissolving surface at the same normalized rate, so release is controlled by the polymer.
- Limit of congruency (LoC): the highest drug loading that still releases congruently; above it drug release drops steeply ("falls off the cliff").
- Normalized release rate: release rate per unit surface area, divided by the component's weight fraction; equal values for drug and polymer mean congruent release.
- AAPS: amorphous-amorphous phase separation; here, water entering the dispersion splits it into drug-rich and polymer-rich amorphous domains.
- LLPS: liquid-liquid phase separation of a solution supersaturated above the amorphous solubility, giving drug-rich nanodroplets.
- Enteric polymer: a polymer such as HPMCAS or Eudragit S 100 that dissolves only once its acid groups ionize above a certain pH.
- Intrinsic dissolution rate (IDR): the dissolution rate per unit area of a compact of one pure material.
03Main findings
The five polymers rank the same way by water uptake and by wetting
PVP is the most hydrophilic polymer and HPMCAS and EUDS the most hydrophobic: at 95% RH PVP took up ≈71 wt% water and HPMCAS ≈10, and buffer contact angles ran from 11.9° (PVP) to 46.8° (HPMCAS). ···
More detail
At 95% RH and 37 °C the polymers took up about 71 (PVP), 47 (PVPVA), 28 (HPMC), 13 (EUDS) and 10 wt% water (HPMCAS); amorphous felodipine took up only about 1.6 wt% at 85% RH, the least of all (single runs, read from Fig. 2). Buffer contact angles were 11.9 ± 0.9° (PVP), 14.6 ± 0.4° (PVPVA), 26 ± 1° (HPMC), 45.9 ± 1.6° (EUDS) and 46.8 ± 5.7° (HPMCAS). The sorption order is HPMCAS ≥ EUDS > HPMC > PVPVA > PVP and the contact-angle order HPMCAS = EUDS > HPMC > PVPVA > PVP; in the abstract the two measurements "suggested" HPMCAS ≃ EUDS > HPMC > PVPVA > PVP. The three hydrophilic polymers are neutral; HPMCAS and EUDS must ionize to dissolve. ····
The hydrophilic polymers release fast only at low loading, then fall off a cliff
PVP and HPMC released congruently up to 10% DL, PVPVA up to 15%. One step higher, drug release from PVP and PVPVA fell about 200-fold (PVPVA ≈1.9 → ≈0.009 mg/min/cm²) while the polymer kept dissolving. ···
More detail
- PVP. At 5 and 10% DL drug and polymer rates matched (≈3.3/≈3.3 and ≈3.8 drug against ≈4.1 polymer, mg/min/cm²) and the solution passed the amorphous solubility (8 µg/mL) within 5-10 min, reaching ≈35 and ≈67 µg/mL at 60 min. From 15% DL drug release fell to ≈0.020, ≈0.010 and ≈0.005 at 15, 20 and 30% DL, and solution concentrations stayed below 1 µg/mL, while PVP itself still dissolved at ≈1.7-1.9. The authors put the LoC at 10% DL. ···
- PVPVA. Up to 15% DL drug and polymer matched (≈2.4/≈2.6 at 5 and 10% DL, ≈1.9/≈1.9 at 15%). At 20 and 30% DL drug release fell to ≈0.009 and ≈0.004 and polymer release to ≈0.14-0.19; LoC 15% DL. ··
- HPMC. Rates matched at 5 and 10% DL (≈0.26/≈0.29 and ≈0.14/≈0.17); at 15% DL drug fell to ≈0.04 against ≈0.16 for polymer, and to ≈0.005 and ≈0.003 at 20 and 30% DL, while polymer release stayed ≈0.19-0.20; LoC 10% DL. ··
- The LoC is reported as the last congruent loading tested in 5% steps, so the switch lies between 10 and 15% (PVP, HPMC) or 15 and 20% DL (PVPVA). ·
- Above the LoC, drug release from PVP and PVPVA (≈0.004-0.020) stays about 5-25 times above that of neat amorphous felodipine (≈0.0008) but about 200-800 times below their congruent rates; the abstract calls these rates "more similar to that of the amorphous drug". ··
- No drug crystallized in solution or on any tablet surface.
The hydrophobic polymers stay congruent up to 50% drug but slow down above 30%
HPMCAS and EUDS released drug and polymer at matching rates at every loading up to 50% DL. HPMCAS held ≈0.82-0.93 mg/min/cm² up to 30% DL, then fell to ≈0.34 at 40% and ≈0.13 at 50%; EUDS stayed at ≈0.07-0.16. ··
See also Fig. 7
More detail
- HPMCAS. Drug and polymer rates matched at all loadings: ≈0.82/≈0.82 (10% DL), ≈0.93/≈0.89 (20%), ≈0.90/≈0.85 (30%), ≈0.34/≈0.31 (40%) and ≈0.13/≈0.13 (50%), against ≈0.77 for neat HPMCAS. Up to 30% DL drug release matched the neat polymer; at 40 and 50% DL both components slowed. Every loading exceeded the amorphous solubility, reaching ≈21, ≈55, ≈76, ≈35 and ≈10 µg/mL at 60 min for 10-50% DL. At 50% DL release began only after a lag, with data plotted from 40 min. ·····
- EUDS (pH 7.4). Rates matched at all loadings and changed little: ≈0.16, ≈0.14, ≈0.15-0.16, ≈0.12-0.13 and ≈0.07 mg/min/cm² from 10 to 50% DL, against ≈0.23 for neat EUDS. The 30-50% DL compacts were plotted only from 25, 80 and 120 min, after a lag the text does not mention. ····
- The authors read the HPMCAS decline as a "penalty": more hydrophobic drug slows polymer dissolution while release stays congruent, as reported earlier for HPMCAS; they place it at "≥40% DL" in the results and "≥30% DL" in the discussion, while the data show the drop between 30 and 40% DL. ··
Faster-dissolving polymers give faster release at low loading; HPMCAS wins at 20-30%
Neat PVP and PVPVA dissolved at ≈3.4-3.6 mg/min/cm², HPMCAS ≈0.77, HPMC ≈0.37 and EUDS ≈0.23, all hundreds to thousands of times faster than amorphous felodipine (≈0.0008). At 20-30% DL HPMCAS released drug about 100-250 times faster than PVPVA. ····
More detail
The printed ratios of polymer to drug dissolution rate are 4600 (PVP), 4300 (PVPVA), 960 (HPMCAS), 460 (HPMC) and 290 (EUDS); EUDS dissolves more than an order of magnitude more slowly than PVP and PVPVA, and the polymer rates do not follow the hydrophobicity order (HPMCAS dissolves faster than HPMC). · Below the LoC the drug follows its polymer, so at 10% DL felodipine released at ≈3.8 (PVP) and ≈2.4 (PVPVA) against ≈0.82 (HPMCAS), ≈0.16 (EUDS) and ≈0.14 mg/min/cm² (HPMC). ···· Fig. 14 plots the crossover: PVPVA ≈2.45 → ≈1.90 from 5 to 15% DL and ≈0.01 at 20%, while HPMCAS holds ≈0.82-0.93 to 30% DL and is "improved" over PVPVA at 20-40% DL in the authors' words (PVPVA was not tested at 40%). EUDS release is low but consistent. Fig. 15 sets the polymer rates beside the LoCs: the fast PVP and PVPVA have LoCs of 10-15% DL, the slower HPMCAS and EUDS none up to 50% DL. ·· An extractor check of Eq. 3 against Fig. S3A gives ≈1.7 rather than ≈3.4 mg/min/cm² for neat PVPVA.
Above the LoC the tablet surface turns porous and drug-rich, and humid films phase-separate
At 30% DL the PVP, PVPVA and HPMC tablets formed a porous surface layer within 10 min, their surface chlorine (felodipine) rose about 1.4-2.8-fold, and their films formed drug-rich domains at 97% RH; HPMCAS and EUDS samples showed none of these. ·····
More detail
- Micro-CT. After 10 min of dissolution, PVP, PVPVA and HPMC tablets at 30% DL showed a porous layer at the dissolving face, "consistent with" their faster polymer release; HPMCAS and EUDS tablets showed no distinct interface and stayed homogeneous with the bulk. ·
- SEM. All initial surfaces were smooth; after 10 min PVP and PVPVA surfaces carried round pores or pits, HPMC was rough with voids, and HPMCAS and EUDS showed angular particles. ··
- EDX. Surface chlorine rose from ≈3.0 to ≈6.7 atomic % (PVP), ≈4.6 to ≈6.4 (PVPVA) and ≈2.6 to ≈7.3 (HPMC), all significant, but stayed at ≈2.9 → ≈3.1 (HPMCAS) and ≈3.0 → ≈2.7 (EUDS), not significant; only felodipine contains chlorine, so the incongruent tablets became drug-rich at the surface. ··
- Confocal films. Films started homogeneous; after 24 h at 97% RH the PVP, PVPVA and HPMC films showed discrete prodan-rich domains, "consistent with phase separation", while HPMCAS and EUDS films stayed uniform at high and low magnification, "suggesting minimal or no phase separation". ·
- All of these samples had 30% DL, above the LoC of the three hydrophilic polymers; no sample below the LoC was imaged. ·
In HPMCAS at 40% loading, more lipophilic drugs release more slowly
Drug release fell from 0.42 (nilvadipine, log P 4.06) to 0.34 (felodipine, 4.46) to 0.26 mg/min/cm² (cilnidipine, 5.40), with polymer release falling alongside (0.42, 0.32, 0.24); all pairs differed significantly. ··
More detail
All three 40% DL HPMCAS dispersions released congruently and more slowly than neat HPMCAS (≈0.77). Drug release differed with p < 0.0001 for every pair, and polymer release with p = 0.0004-0.0249. The extrapolated water uptake at 100% RH fell slightly in the same order (≈5.83, ≈5.67, ≈5.45 wt%, overlapping error bars). The authors say this "substantiates the supposition" that drug hydrophobicity influences release, "at least" for congruent systems at high loading, and that "it seems likely" there is a cutover loading above which the drug starts to dominate, since at low loading an earlier study found no log P effect. ······
The polymers that hydrogen-bond most strongly to felodipine have the lowest LoCs
The felodipine NH band (3342 cm⁻¹ in the neat glass) moved down about 50 cm⁻¹ with PVP and PVPVA (stronger bonds), hardly with HPMC, and up with HPMCAS and EUDS (weaker bonds); PVP and PVPVA have LoCs of 10-15% DL, HPMCAS and EUDS none up to 50%. ···
More detail
NH positions were 3292 (PVP), 3293 (PVPVA), 3344 (HPMC), 3354 (EUDS) and 3362 cm⁻¹ (HPMCAS) in Table 3, against 3342 for amorphous felodipine; in Fig. 13 the EUDS and HPMCAS maxima appear the other way round (≈3362 and ≈3355). For HPMC the carbonyl doublet (1701 and 1682 cm⁻¹) merged into one band at 1699 cm⁻¹, which the authors read as an interaction of similar strength to that in the neat drug. Their order of hydrogen-bond strength is PVP ≅ PVPVA > HPMC > HPMCAS > EUDS; a residual 3342 cm⁻¹ shoulder in most ASDs means the extent of drug-polymer bonding cannot be quantified. They "observe no positive correlation" between bond strength and LoC and conclude that the role of interactions, "if any", needs further evaluation. In this polymer set, bond strength and hydrophilicity rise together, so the two cannot be separated. ·····
04Further observations
- Felodipine solubility is 1.3 µg/mL crystalline and 8 µg/mL amorphous (ratio 6); 1000 µg/mL of any polymer leaves the crystalline value unchanged (0.9-1.4). ··
- No drug crystallized during any dissolution test.
- From PVP ASDs below the LoC, felodipine passed the amorphous solubility within 5-10 min; from HPMCAS ASDs every loading passed it during the run. ·
- High-loading HPMCAS and EUDS compacts released only after a lag. ··
- Higuchi's critical drug:polymer ratio for Fel-PVPVA is tiny, so any practical loading lies above it. ··
More detail
- Solubility. Crystalline felodipine dissolved to 1.3 ± 0.3 µg/mL and amorphous felodipine to 8 ± 1 µg/mL in pH 6.8 buffer at 37 °C, within experimental error of earlier values; with 1000 µg/mL polymer the crystalline solubility was 1.2 ± 0.2 (PVP), 1.1 ± 0.0 (PVPVA), 1.3 ± 0.1 (HPMC), 0.9 ± 0.3 (HPMCAS) and 1.4 ± 0.1 µg/mL (EUDS, pH 7.4). The authors call felodipine's ≈6-fold amorphous advantage "modest" and its IDR "extremely low", which they say shows that amorphization alone is "unlikely" to be enough. ···
- Supersaturation. With PVP, 10% DL reached the amorphous solubility at the first sample (5 min) and ≈67 µg/mL by 60 min, 5% DL ≈35 µg/mL; with HPMCAS every loading exceeded 8 µg/mL, the 50% DL compact only near the end (≈10 µg/mL at 60 min). Drug samples were not filtered, so these values include any drug-rich colloids. ··
- Lags. The 50% DL HPMCAS compact was plotted from 40 to 90 min; the EUDS 30, 40 and 50% DL compacts from 25, 80 and 120 min, up to 160 min, although the method states 1 h runs. The rates for these compacts are slopes after the lag. ··
- Higuchi ratio. With an amorphous solubility of 8 µg/mL, a PVPVA solubility of 46 mg/mL and a diffusion-coefficient ratio of 10, the critical ratio is printed as 1.7 x 10⁻⁶ (the inputs give 1.7 x 10⁻³); either way it is far below 1% drug. ··
- Fresh dispersions. All fresh ASDs were amorphous and showed one glass transition each, which the authors take to mean molecular dispersion. ·
05How the authors connect the findings
More detail
- Felodipine is a BCS class II drug whose amorphous form is only about 6 times more soluble than its crystal and dissolves at ≈0.0008 mg/min/cm². Neat polymers dissolve 290-4600 times faster, so the in vivo benefit of an ASD "most likely" comes from polymer-controlled release, and exploiting it is "likely essential"; loading decides whether it can be achieved. ····
- Higuchi's diffusion model allows congruent release only at a critical drug:polymer ratio (Eq. 4), which is tiny for an ASD, so at any real loading release should start diffusion-controlled and leave a drug-rich porous layer. The model "may" describe high-loading ASDs but fails for the congruent release seen up to 10-15% DL. Corrigan's argument that low loadings hold too little drug for an intact layer "doesn't seem to hold true" as the sole explanation, because the PVPVA LoC varies 5-25% with the drug and HPMCAS and EUDS stay congruent to 50% DL; judging by drug:polymer ratio alone is "clearly an over simplification". ·····
- Water lowers the miscibility of some ASDs, and earlier work from the group showed that AAPS turns congruent into incongruent release. The authors propose a race. If dissolution is faster than AAPS, "thought to be the case" for the ≤10% DL ASDs here with any polymer, drug and polymer leave together and the surface keeps its composition. If AAPS is faster, drug-rich and polymer-rich domains form and dissolve at rates set by their compositions. ··
[+] Low loading or low water uptake. Too little drug to form a contiguous drug-rich layer, and "may also be" a lower tendency or slower kinetics of AAPS → release stays congruent ("likely"). With HPMCAS and EUDS, which take up less water (Fig. 2), the water absorbed is "conceivably" too little to cause AAPS even at high loading; the uniform films after 97% RH are the "support for the conjecture". ···
[-] Higher loading in PVP, PVPVA or HPMC. A greater tendency or rate of AAPS → polymer-rich domains dissolve first → the surface becomes drug-rich (more chlorine) and porous (micro-CT, SEM) → this layer is a physical barrier to polymer release from below and lowers drug release towards that of neat amorphous drug. The tablet data "supported" this sequence at 30% DL. ·····
- In congruently releasing HPMCAS dispersions, increasing loading imposes a "penalty" on both components, and at 40% DL the penalty grows with drug log P; the authors relate this to the system's overall hydrophobicity becoming dominated by the drug ("it seems likely"). HPMCAS and EUDS must ionize to dissolve, so their interactions with water and drug differ between the dry and hydrated states. ···
What sets the switch point. The thermodynamics and kinetics of AAPS depend on loading and on the water absorbed, so polymer hygroscopicity "likely also plays a role". Drug-polymer hydrogen bonding, which earlier work suggested "may" resist AAPS, showed "no positive correlation" with the LoC. ··
Conclusion drawn. "Water-induced AAPS is likely the cause" of the dramatic decline with the more hydrophilic polymers. Hydrophilic polymers give faster release in the low-loading regime, and "more slowly dissolving polymers may yield improved drug release rates at higher drug loadings": a "trade-off". ·
06What it means for formulation
- Keep the loading at or below the LoC in PVP and PVPVA dispersions ("crucial").
- Hydrophilic polymers "may be a better choice" below the LoC; a hydrophobic polymer "may allow" better release at higher loading.
- For a high-dose, very insoluble drug, HPMCAS can deliver more drug per minute than PVPVA once the loading must exceed the PVPVA LoC.
- Hydrogen bonding chosen for stability did not protect release here.
More detail
- It is "crucial" to keep the loading at or below the LoC in these ASDs to avoid severely compromised dissolution and bioavailability.
- The PVPVA pattern "may underlie" the human data for grazoprevir-PVPVA tablets, where moving from a 30% to a 40% DL ASD intermediate halved bioavailability and neat amorphous drug gave less than a quarter of it. ·
- More hydrophilic polymers "may be a better choice" at low loading (below the LoC) because they dissolve faster; a more hydrophobic polymer "may allow" better release at somewhat higher loading. The choice depends on the dissolution profile needed for exposure and on the dose (Fig. 15).
- The LoC of an ASD compact "may not coincide exactly" with that of the final dosage form: surfactants have improved the LoC, disintegrating tablets may behave differently, and inorganic salts can improve release at high loading.
- Making a very poorly soluble drug amorphous is "unlikely" to be enough on its own; the polymer must control release. ·
- With felodipine, PVPVA delivers the fastest release up to 15% DL, but at 20-30% DL HPMCAS releases about 100 times more drug per minute; for a dose that forces a loading above about 15%, a hydrophobic enteric polymer is the safer choice in this system, at the cost of slower release than PVPVA at low loading.
- The LoCs are brackets set by 5% loading steps (10-15% or 15-20%); a formulation meant to sit just below a LoC needs finer steps around it.
- Measuring polymer release as well as drug release shows directly whether a formulation is on the congruent side; drug release alone at a single loading cannot.
- The strongest drug-polymer hydrogen bonding (PVP, PVPVA) came with the lowest LoCs, so selecting a polymer for interaction strength, often done for physical stability, does not protect release in this system.
- HPMCAS and EUDS need ionization to dissolve; their advantage at high loading assumes a medium pH where they dissolve (pH 6.8 and 7.4 here).
07Open questions
- What role, if any, do drug-polymer interactions play in setting the LoC?
- Does the LoC of a compact hold in a disintegrating dosage form with excipients?
- At what loading do drug properties start to dominate release?
- Phase separation was not observed in the dissolving tablets, nor at any loading below the LoC.
- Water uptake does not rank the LoC among PVP, PVPVA and HPMC.
More detail
- The role of drug-polymer interactions, "if any", in determining the LoC "clearly needs further evaluation".
- The effect of additional excipients on the LoC of ASD formulations "has not been widely investigated"; disintegrating formulations "may behave differently" from compacts.
- "It seems likely" that there is a cutover loading where drug properties start to substantially affect release; it was not located.
- AAPS was seen only in 30% DL films after 24 h at 97% RH, and the tablet surfaces were imaged only at 30% DL after 10 min; nothing was imaged at or below the LoC, so the claim that AAPS sets the LoC is not tested at the switch itself. ·
- Neat-polymer water uptake separates the two polymer groups but does not order the LoC within the hydrophilic group: HPMC takes up less water than PVPVA yet has the lower LoC.
- Hydrogen-bond strength and hydrophilicity rise together across these five polymers, so their effects on the LoC cannot be separated.
- LLPS below the LoC is inferred from concentrations, not detected.
- One model drug (two analogues only at 40% DL in HPMCAS), non-disintegrating compacts, one temperature, and EUDS at a different pH. ·
08How solid
AI assessment, not a statement made in the paperThe release patterns are direct, replicated (n = 3) and consistent across five polymers, and two independent measurements rank hydrophobicity the same way. The mechanism, AAPS controlled by water uptake, rests on one loading, humid films and indirect surface data, and the hygroscopicity argument does not order the hydrophilic polymers. ····
More detail
- Drug and polymer release were both measured for every compact, so congruency is read directly; the LoCs of PVP, PVPVA and HPMC and the congruent release of HPMCAS and EUDS to 50% DL are clear in the data. ·
- Water sorption and contact angle agree on the hydrophobicity order. ·
- The surface data at 30% DL agree with each other: porosity, chlorine enrichment and humid-film domains appear only for the three hydrophilic polymers. ··
- The log P series gives a monotonic, statistically significant fall in both rates. ·
- AAPS was not observed in the dissolving compacts, and no sample at or below a LoC was imaged; the porous, drug-rich surfaces also follow from faster polymer than drug dissolution alone. ·
- Hygroscopicity was measured on neat polymers in single runs and does not rank the LoC among PVP, PVPVA and HPMC.
- Hydrogen-bond strength and hydrophilicity are confounded in this polymer set, and the Table 3 and Fig. 13 positions for HPMCAS and EUDS disagree. ·
- The LoCs are resolved only to 5% steps; high-loading HPMCAS and EUDS rates are post-lag slopes; the neat-PVPVA rate is not reproduced by its own release curve. ··
- One drug; EUDS was tested at pH 7.4 rather than 6.8; the Higuchi ratio is misprinted by a factor of 1000 (without effect on the argument). ·
09Figure guide
Every figure and table of the paper, what it is there for, and what to check on the original. Key figures are shown with the story.
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Fig. 1 (p.3)key figure | Defines the systems: three dihydropyridines and five polymers of different chemistry.······· | 0.2 | |
| Table 1 (p.5) | Felodipine solubility, 1.3 crystalline and 8 µg/mL amorphous, the reference line for supersaturation. | 0.4 | |
| Fig. 2 (p.5)key figure | Ranks hydrophobicity by water uptake: PVP most, HPMCAS and EUDS least. | F1, K5 | Single runs; neat polymers, not ASDs. |
| Table 2 (p.5) | Ranks hydrophobicity by contact angle, the same order as sorption. | F1 | |
| Fig. 3 (p.6) | PVP release profiles: drug follows polymer at 5-10% DL, stays below 0.5% from 15% DL. | F2 | |
| Fig. 4 (p.7) | HPMCAS release profiles: drug follows polymer at all loadings; lag at 50% DL. | F3 | 50:50 runs to 90 min, beyond the stated 1 h. |
| Fig. 5 (p.8)key figure | Felodipine concentrations from PVP ASDs against the amorphous solubility. | F2 | LLPS inferred, not measured. |
| Fig. 6 (p.8) | Felodipine concentrations from HPMCAS ASDs, all above the amorphous solubility. | F3 | |
| Fig. 7 (p.9)key figure | The central data: drug and polymer rates against loading for five polymers, with LoC arrows.·· | F2, F3, K1 | Broken y-axes; LoCs are brackets; neat-PVPVA bar not reproduced by Fig. S3A.· |
| Fig. 8 (p.10)key figure | Release falls with drug log P at 40% DL in HPMCAS. | F6, K6 | Interactions of the analogues not measured. |
| Fig. 9 (p.10)key figure | Porous surface layer only for the three hydrophilic polymers at 30% DL. | F5, K3 | One loading, above the LoC. |
| Fig. 10 (p.11) | Pits on PVP and PVPVA surfaces after 10 min; particles on HPMCAS, EUDS. | F5 | |
| Fig. 11 (p.11)key figure | Surface drug enrichment (chlorine) only for the incongruent tablets. | F5, K3 | Initial PVPVA chlorine higher than the others. |
| Fig. 12 (p.12)key figure | Phase separation in humid films of the three hydrophilic polymers only. | F5, K4 | Films at 97% RH for 24 h, not dissolving tablets. |
| Fig. 13 (p.12)key figure | NH band shifts that rank hydrogen bonding. | F7, K7 | EUDS and HPMCAS maxima reversed relative to Table 3. |
| Table 3 (p.12) | NH peak positions for the drug and five ASDs. | F7 | Two entries look swapped. |
| Fig. 14 (p.13)key figure | Crossover of PVPVA and HPMCAS drug release with loading. | F4, K2 | High-loading rates exclude the lag. |
| Fig. 15 (p.14)key figure | Trade-off summary: polymer dissolution rate against LoC.· | header, K2 | The 50% points mean "no LoC up to 50%". |
More detail
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Fig. S1, Table S1 (SI p.2-3) | One Tg per fresh ASD; Tg of the pure components.· | 0.4 | Table S1 unit not printed. |
| Fig. S2, Table S2 (SI p.3-4) | Example contact-angle drops; crystalline solubility unchanged by polymers.· | F1, 0.4 | |
| Figs. S3-S5 (SI p.5-7) | Release profiles for PVPVA, HPMC and EUDS.·· | F2, F3 | EUDS 30-50% DL plotted from 25-120 min; neat-PVPVA slope gives ≈1.7, not ≈3.4.· |
| Tables S3, S4 (SI p.8) | Rates and statistics of the log P series.· | F6 | |
| Figs. S6, S7 (SI p.9) | Smooth initial tablet surfaces; uniform HPMCAS and EUDS films at low magnification.· | F5 | Fig. S7 caption refers to Fig. 13 for Fig. 12. |
| Fig. S8 (SI p.10) | Carbonyl band of felodipine with HPMC. | F7 | |
| Fig. S9, Section S4 (SI p.11) | Extrapolated water uptake of the log P series; Higuchi critical ratio.· | F6, 0.4 | Truncated axis; printed ratio off by 1000.· |