How does the polymer of a ritonavir ASD change the drug's thermal degradation at hot melt extrusion temperatures, and is the effect explained by molecular mobility, drug–polymer interactions or drug–polymer chemical compatibility?
Polymer type was the main factor: after 5 min at 180 °C in the TGA, about 76% of RTV remained with PVP K-30 and 59% with PVP/VA 64, against 38% for neat RTV and almost none with HPMCAS or HPMC. Drug loading, polymer grade and Tg did not explain the differences; the authors attribute them to protic polymers promoting RTV hydrolysis, which was not measured directly. ·····
For 20% DL RTV dispersions held 5 min at 120–180 °C under nitrogen, aprotic PVP and PVP/VA protected RTV relative to neat drug from 160 °C upward, protic HPMCAS and HPMC accelerated its degradation, and HME at 130–160 °C kept the same rank order with far less degradation. ··· The main degradant, P4, is RTV minus water; the authors propose that this water "can then catalyze" the hydrolysis that forms the other six products and that protic polymers, through acids released from their substituents, promote these reactions; neither the sequence nor any acid release was measured. ···· Molecular mobility (Tg, drug loading, polymer grade) and drug–polymer interactions gave "Limited evidence", the interaction evidence being "somewhat tenuous". ·· Isothermal TGA rank-orders drug–polymer compatibility but overpredicts HME degradation, and TGA mass loss misranks the polymers; the authors call it "essential" to couple TGA screens with HME and suggest that a convection oven "may be" a better screen. ··
01Why this study
HME exposes drug and polymer to high temperature and shear; degradation depends on cumulative time and temperature, and processing needs 15–60 °C above the polymer Tg, about 130 °C or more for PVP/VA and HPMCAS.
Moseson 2020, ref 3; Li 2016, ref 8 ·
It melts at 126 °C, is extruded commercially and is known to degrade under typical extrusion conditions.
Zhao 2019, ref 9; LaFountaine 2016, ref 10; Kaushik 2016, ref 11
In TGA, polymers lowered the degradation onset of posaconazole but delayed that of indomethacin, and PVP or cellulose acetate protected or destabilized drugs depending on interactions.
Moseson 2020, ref 3; Ben Osman 2018, ref 14; Ferreira 2020, ref 16
More detail
What was already known. The introduction builds on these points:
- Heat and shear in HME. Forming ASDs by HME exposes drug and polymer to high temperature and shear, and drug and/or polymer may degrade from cumulative exposure (time and temperature); a thermally stable process is needed for product identity, strength, quality, purity and potency. (Huang 2018, ref 1; Ma 2019, ref 2; Moseson 2020, ref 3; DiNunzio 2010, ref 4; ICH Q3B(R2), ref 5)
- The temperature floor. Crystalline drugs commonly degrade rapidly on melting, so the lowest possible temperature is preferred, but the melt must be processable: 15–60 °C above the polymer Tg, which puts practical temperatures at around 130 °C and above for PVP/VA and HPMCAS. (Moseson 2018, ref 6; Evans 2018, ref 7; Li 2016, ref 8)
- Ritonavir. With Tm 126 °C, RTV is manufactured commercially as an HME ASD and degrades under typical extrusion conditions, so finding a polymer that allows processing while limiting degradation is "inherently challenging". (refs 9–11)
- Polymer choice is usually made for other reasons. Crystallization inhibition dominates polymer selection; melt viscosity, thermoplasticity and thermal stability matter for processing; the polymer's effect on drug chemical stability is often overlooked and its mechanisms are not fully elucidated. (Van Duong 2016, ref 12; LaFountaine 2016, ref 13)
- Earlier evidence of polymer effects. In the group's TGA study, polymers lowered the degradation onset of posaconazole, with PVP/VA possibly more protective than HPMCAS, while PVP/VA delayed the onset of indomethacin (Moseson 2020, ref 3). Vyazovkin and colleagues found PVP protective or destabilizing for indomethacin depending on interactions and drug–polymer ratio (Ben Osman 2018, ref 14; Jelić 2019, ref 15), and cellulose acetate protected ibuprofen and naproxen, suggested to be through hydrogen bonding (Ferreira 2020, ref 16). The authors conclude that the stabilization mechanism is complex.
What the paper set out to do. Investigate how polymers stabilize or destabilize RTV against thermal degradation: prepare RTV ASDs with PVP, PVP/VA, HPMC and HPMCAS, expose them isothermally in a TGA and an oven at HME-like temperatures, compare with HME, identify the degradants and their pathways by LC-MS/MS, and test three possible mechanisms: molecular mobility (Tg), intermolecular interactions and drug–polymer compatibility. ···
02How they approached it
One drug at 20% DL, close to the commercial Norvir loading, with four polymer families heated as in HME; degradation read as remaining RTV by HPLC rather than as mass loss. Grades and loadings change Tg while keeping the chemistry, to separate mobility from chemistry. ·····
What was done
RTV and polymer from methanol by rotary evaporation, 20% DL (10–50% DL for PVP K-30 and PVP/VA 64)→DSC and XRPD→one Tg, amorphous.···
Neat RTV in nonisothermal TGA at 1–10 °C/min→degradation onset.·
ASDs held 5 min at 120–180 °C in the TGA under nitrogen→HPLC assay of remaining RTV.·
60 min isothermal TGA→mass loss.··
Assay across loading, PVP grade, PVP/VA grade and T/Tg→one-way ANOVA.···
FT-IR of spin-coated films→band shifts.·
LC-MS/MS of RTV-HPMCAS LF after 170 °C→masses and fragments of seven degradants.··
HME at 130–160 °C, 5 min, with PVP/VA 64, HPMCAS MF and HPMC→assay and degradant sum.·
Convection oven vs TGA at 160 °C up to 30 min→first-order rates.··
HME vs 5 min oven and TGA assays at 160 °C.
More detail
What was done
- ASDs. RTV and each polymer were dissolved in methanol, dried in a rotary evaporator at 45 °C and overnight under vacuum, and cryomilled; 20% DL was made with every polymer and 10–50% DL with PVP K-30 and PVP/VA 64. DSC (modulated, second heating, n = 3) gave one Tg per ASD, and XRPD showed halos only. ····
- Onset of degradation. Neat RTV was heated in a TGA at 1, 2, 5 and 10 °C/min; the onset was taken at 0.1, 0.5 and 1.0% weight loss after normalizing to 100% at 120 °C, or by tangent intersection. ··
- Isothermal exposure. ASD powders and neat RTV were held 5 min at each temperature from 120 to 180 °C in the TGA under nitrogen, dissolved in acetonitrile and assayed by HPLC against an unheated reference. The 5 min hold matches the HME residence time. ··
- Mass loss. Separate TGA runs held RTV, polymers and ASDs for 60 min at 120–180 °C (ramp 50 °C/min, duplicate). ····
- Mobility tests. Loading (10–50% DL) and polymer grade (PVP K-12 to K-90; PVP/VA 37, 64, 73) were varied and tested by one-way ANOVA; assay was plotted against the hold temperature over the ASD Tg (T/Tg, in kelvin). ······
- Interactions. Spin-coated films of RTV, polymers and ASDs were measured by transmission FT-IR. ···
- Degradants. The 170 °C RTV-HPMCAS LF sample, which showed all seven degradants with RTV still present, was analysed by LC-Q-ToF MS/MS (positive ESI) to give exact masses, formulas and product ions. ···
- HME. Physical mixtures (20% DL) with PVP/VA 64, HPMCAS MF or HPMC were extruded in a 2 mL Xplore twin-screw extruder at 50 rpm with 5 min residence (from start of feeding to valve opening) at product melt temperatures of 130–160 °C, in triplicate. PVP K-30 was left out because of its high Tg and viscosity, HPMCAS LF because it was worse than MF. ··
- Oven vs TGA. About 7 mg of neat RTV, RTV-PVP/VA 64 and RTV-HPMC were held at 160 °C for 2–30 min in a convection oven or the TGA (nitrogen purge), in triplicate, and ln(assay) was fitted against time. ··
Key equations
The hold temperature divided by the ASD glass transition temperature, both in kelvin; used to put all ASDs on one mobility scale (for RTV-HPMC at 180 °C, 453.15/327.45 = 1.38).
A is the RTV assay (%), t the time in seconds and k the rate constant; straight lines (R² 0.982–0.999) were taken as first-order kinetics, and the fitted lines give the 5 min oven and TGA values compared with HME.
Terms used on this page
- Assay: the RTV remaining after heating, as % of an unheated reference measured by HPLC.
- Tonset: the temperature at which a heated sample starts to lose mass in a TGA scan; it depends on heating rate and on how it is read.
- Protic / aprotic polymer: the authors' grouping of polymers with substituents that can give or take protons (HPMCAS with acetyl and succinoyl groups, HPMC with hydroxypropoxy groups) against those without (PVP, PVP/VA).
- Dehydration / hydrolysis: loss of a water molecule from RTV (P4) / cleavage of RTV bonds by water (the other degradants).
- ppm mass error: the difference between measured and calculated mass in parts per million; below 5 ppm supports the assigned formula.
- Residence time: the time the melt spends in the extruder.
03Main findings
PVP and PVP/VA protect ritonavir; HPMCAS and HPMC accelerate its loss
After 5 min at 180 °C, RTV assay was about 76% with PVP K-30, 59% with PVP/VA 64 and 38% neat, but about 3.5% with HPMCAS MF and 0% with HPMCAS LF and HPMC. The protection over neat RTV shows from 160 °C. ·
More detail
After 5 min isothermal TGA holds, the assay of neat RTV fell from about 100% at 140 °C to about 82, 63 and 38% at 160, 170 and 180 °C. RTV-PVP K-30 kept about 93, 88.5 and 76% and RTV-PVP/VA 64 about 91, 79.5 and 59% at the same temperatures. The cellulose polymers were worse than neat drug from the lowest temperature: at 120 °C RTV-HPMC already held only about 88% and RTV-HPMCAS LF about 93%; at 150 °C about 47.5% (HPMC), 67.5% (LF) and 76.5% (MF) remained, and at 180 °C almost nothing. HPMCAS MF was less harmful than LF at every temperature. The overall order was PVP K-30 > PVP/VA 64 > neat RTV > HPMCAS MF > HPMCAS LF > HPMC, which the authors read as protection by PVP and PVP/VA and acceleration by HPMCAS and HPMC. · Their claim of "distinctly less degradation" than neat RTV "over the entire temperature range" holds from 160 °C; up to 150 °C neat RTV, PVP K-30 and PVP/VA 64 all kept about 95.5–102%. · The chromatograms show the same picture: degradant peaks grow with temperature, small for PVP K-30 and PVP/VA 64 even at 180 °C, while the RTV peak is small or gone at 180 °C for the HPMCAS and HPMC sets. The solid form of the neat RTV that was heated is not stated, which matters at 120 °C, below its melting point.
Neither drug loading, polymer grade nor Tg explains the differences
Assays at 10–50% DL and across PVP and PVP/VA grades did not differ significantly (P 0.775–0.997), although ASD Tg ranged from 53 to 147 °C; plotted against T/Tg, the systems did not fall on one curve. ····
More detail
Raising DL from 10 to 50% lowered the ASD Tg from 146.9 to 80.4 °C (PVP K-30) and from 97.1 to 53.2 °C (PVP/VA 64), yet one-way ANOVA found no difference among loadings (F 0.445 and 0.041 against F critical 2.690; P 0.775 and 0.997), and the authors conclude the protection does not depend on DL. ·· At 180 °C the PVP/VA 64 assays did spread from about 58–59.5% (10–20% DL) to about 48% (50% DL), and PVP K-30 at 10% DL was lower than the others between 140 and 170 °C; the ANOVAs pool all seven temperatures in each group, so they do not test differences at a given temperature. · The four PVP grades (ASD Tg 86.1–135.4 °C) kept about 78–83% at 180 °C, with no significant difference (P 0.935); because the grades differ in molecular weight and so viscosity, "we infer" that global polymer mobility is not a major factor. ··· Among PVP/VA grades, PVP/VA 64 and 73 did not differ (P 0.852), but PVP/VA 37, with the most vinyl acetate, kept only about 50.5% at 180 °C against 59 and 63%; the authors take this to mean the PVP portion "may improve chemical stability" through favourable interactions; PVP/VA 37 was not included in a statistical test. ···· Against T/Tg (Fig. 6) the ASDs of different polymers spread over different ranges, from about 0.98–1.13 for PVP K-30 to 1.20–1.38 for HPMC. Across polymer types stability "generally increases" with Tg, except that HPMCAS MF (Tg 72.6 °C) was more stable than LF (75.0 °C), while grades and loadings with very different Tg gave similar degradation; the authors conclude there is "no clear correlation" and that the data "hint" at polymer chemistry. ·· They add that Tg is only a crude indicator of mobility. The discussion later states that no correlation was found across polymer types, which reads more strongly than the results. ·
FT-IR finds only weak signs of drug–polymer interaction
The ASD spectra barely changed: small shifts for HPMC (1639 and 1722 cm⁻¹), a 1720 cm⁻¹ shoulder for PVP K-30 and a broadened 1681 cm⁻¹ band for PVP/VA 64, none for HPMCAS. ··
More detail
Amorphous RTV has its carbamate C=O at 1716 cm⁻¹ and amide C=O at 1633 cm⁻¹; PVP K-30 has its C=O at 1681 cm⁻¹, PVP/VA 64 C=O bands at 1735 (vinyl acetate) and 1683 cm⁻¹ (vinyl pyrrole). In the ASDs the authors found it "not possible to detect notable changes". RTV-HPMCAS LF and MF showed no shifts or new bands. RTV-HPMC showed RTV's two carbonyl bands at 1639 and 1722 cm⁻¹, which "might indicate" drug–polymer interactions that disrupt RTV's own interactions. RTV-PVP K-30 showed a shoulder at 1720 cm⁻¹ that might reflect changed hydrogen bonding or simple band overlap, and RTV-PVP/VA 64 a slightly shifted, broadened 1681 cm⁻¹ band that "may suggest" interaction at the vinyl pyrrole carbonyl, as seen before (Siriwannakij 2020, ref 27). ·· In the discussion the authors call this spectral evidence "somewhat tenuous".
Seven degradants; P4, ritonavir minus water, dominates
LC-MS/MS assigned seven degradants within 5 ppm; P4 (m/z 703, 18 Da below RTV) gave the largest degradant peak, and P2–P4 had not been reported before. ···
More detail
In the RTV-HPMCAS LF sample heated to 170 °C, HPLC showed RTV (about 19.5 mAU) and seven degradant peaks, the largest P4 (about 47.5 mAU) and P2 (about 39 mAU). P4 is the largest degradant peak in every degraded set. Exact masses fitted the assigned formulas with errors of −1.48 to 3.96 ppm: RTV C37H49N6O5S2+ (721.3192), P1 C8H15N2S+ (171.0951), P2 C12H19N2O3S+ (271.1107), P3 C10H17N2OS+ (213.1059), P4 C37H47N6O4S2+ (703.3093), P5 C29H35N4O5S+ (551.2319), P6 C25H30N3O4+ (436.2225) and P7 C33H44N5O4S+ (606.3127). · Two printed theoretical masses (P5, P7) and the P1 error do not match their formulas, but every error stays below 5 ppm. From the product ions the authors place P1 and P2 as small thiazole-containing fragments (P2 contains P1), P3 from reaction of the two amide groups, P4 as RTV minus water, P5 as a cyclized product that keeps the main RTV structure, P6 as an oxazolidone that lost the thiazole portion, and P7 as related to P6. · P1, P5, P6 and P7 had been reported as hydrolysis products in forced degradation studies (Rao 2010, ref 36; Koppala 2015, ref 37; Tiwari 2011, ref 38); P2–P4 are new, which the authors relate to temperatures beyond typical forced degradation. · The structures rest on mass data only.
TGA mass loss does not track degradation
After 5 min at 180 °C the HPMCAS ASDs had lost no more than 1.5% of their mass while their RTV assay fell to about 0–3.5%; the authors conclude mass loss is not a reliable estimate. ··
More detail
Over 60 min at 180 °C neat RTV lost 36.4% of its mass and RTV-HPMC 9.1%, the others less (about 92–99% remaining); after 5 min these two had lost 8.0 and 6.4% and all other ASDs at most 1.5%. At 120–140 °C RTV-HPMC lost as much as or more than neat RTV over 60 min, at 150–170 °C much less (about 91% vs 67.5% remaining at 170 °C). Neat polymers kept at least about 96.4% of their mass. The mass loss therefore ranks neat RTV as the least stable, whereas assay ranks it in the middle. · The authors conclude that mass loss "is not a reliable estimate" of RTV degradation, and in the discussion that mass loss is "underpredictive/incorrect", suggesting only that HPMC accelerated degradation. · Nonisothermal TGA was similarly ambiguous: the onset of neat RTV ranged from about 134.5 to 213.5 °C depending on heating rate and criterion (text: 135–214 °C), so conclusions from nonisothermal scans alone "may be misleading". ··
HME and an oven degrade ritonavir far less than isothermal TGA, in the same order
After HME at 160 °C, RTV assay was 98.4% with PVP/VA 64, about 97% with HPMCAS MF and 95.7% with HPMC, against about 91, 54 and 22% after 5 min at 160 °C in the TGA; at 5 min a convection oven gave 98.7 and 82.9%, and TGA rates were up to about 5 times the oven rates. ····
More detail
All three systems extruded at 130–160 °C and stayed amorphous. Assays stayed between about 95.7 and 100.5%, and the summed degradant areas rose with temperature to about 1.1% (PVP/VA 64), 2.3% (HPMCAS MF) and 6.3% (HPMC) at 160 °C; only PVP/VA 64 extrudates made at 130 and 140 °C stayed under 0.5% total degradants. · The authors rank stability PVP/VA 64 > HPMCAS MF > HPMC "at all temperatures", as in the TGA; the degradant sums follow this order at every temperature, while the assays at 130–140 °C overlap within error. · Three of the seven degradants, P4, P5 and P6, appeared in the extrudates (labelled P1–P3 in Fig. S12). · HPMCAS MF and HPMC extrudates were yellow and darkened slightly with temperature, which "may suggest" degradation; PVP/VA 64 extrudates stayed clear. · At 160 °C over 30 min the oven left about 86% (PVP/VA 64), 77.5% (neat RTV) and 18.5% (HPMC), the TGA about 76, 23 and 0%; ln(assay) fell linearly with time in every case, and the fitted rate for neat RTV was 8.15 × 10⁻⁴ s⁻¹ in the TGA against 1.52 × 10⁻⁴ s⁻¹ in the oven. ·· For 5 min at 160 °C the paper compares HME, oven and TGA as 98.4, 98.7 and 95.3% (PVP/VA 64) and 95.7, 82.9 and 30.2% (HPMC); the oven and TGA values reproduce the fitted lines rather than plotted points. · The authors conclude that HME degraded RTV far less than TGA predicted and that the oven results were "similar" to HME. · They suggest the TGA's heating from room temperature and its nitrogen purge, which "may have eliminated" volatile products, as reasons; the shorter effective exposure in the extruder, where residence is counted from the start of feeding, is not discussed. ·
04Further observations
- Every ASD, from solvent or from the extruder, showed one Tg and an amorphous XRPD halo. ··
- Drug loading lowered the ASD Tg by up to 89.9 °C (PVP K-30, 50% DL).
- HPMCAS MF and HPMC extrudates turned yellow; PVP/VA 64 extrudates stayed clear.
- Neat polymers lost little mass on heating, at most about 3.6%.
More detail
- One phase, amorphous. Each 20% DL ASD had a single Tg between 54.3 (HPMC) and 135.4 °C (PVP K-90), which the authors read as a single-phase amorphous system, and XRPD showed only halos for every solvent-evaporated ASD and every extrudate; neat RTV was crystalline with a melting endotherm near 126 °C. ···
- Tg falls with loading. ASD Tg dropped from 146.9 to 80.4 °C (PVP K-30) and from 97.1 to 53.2 °C (PVP/VA 64) between 10 and 50% DL, a ΔTg of up to 89.9 and 57.3 °C below the neat polymer. ·
- Extrudate colour. RTV-PVP/VA 64 extrudates were clear and colourless at every temperature, RTV-HPMCAS MF and RTV-HPMC extrudates yellow and slightly darker at higher temperature. ·
- Polymers are stable by mass. After 60 min at up to 180 °C the neat polymers kept at least about 96.4% of their mass, the largest loss being PVP K-17; the authors did not study polymer degradation further. ·
- Choice of HME polymers. PVP K-30 gave the best TGA stability but was not extruded because its high Tg and viscosity would need much higher temperatures.
05How the authors connect the findings
More detail
- At HME-like temperatures neat RTV degrades extensively, in agreement with earlier reports (refs 9–11); P4, formed by dehydration, is the main degradation product. ··
- RTV is known to hydrolyse (refs 36–38). The water released when P4 forms "can then catalyze" the formation of P1–P3 and P5–P7, so the degradation becomes self-catalysed; Fig. 10 draws each route as acid-catalysed attack on intact RTV. ··
- Most of these hydrolysis products form by intramolecular attack, so intermolecular interactions "may protect" the RTV molecule; the FT-IR shifts, "perhaps indicative" of hydrogen bonding, lie in regions of the more reactive groups, and the better protection by PVP than by PVP/VA is "possibly due to" more interactions with the vinyl pyrrole carbonyl. The authors call this evidence "somewhat tenuous". ·
[+] Aprotic PVP and PVP/VA. Without protic substituents the polymer adds nothing that catalyses hydrolysis, and RTV degrades less than as neat drug from 160 °C upward. ··
[-] Protic HPMCAS and HPMC. HPMCAS (acetyl 5–11%, succinoyl 10–18%) can hydrolyse at high temperature to free acetic and succinic acid that can react with RTV (refs 24, 39, 40); as all degradants form by processes catalysed by hydrogen or hydroxyl ions, the higher succinoyl content of HPMCAS LF "rationalizes" its greater effect than MF. HPMC, the worst, carries the most methoxy (28–30%) and hydroxypropoxy (7–12%) groups. ···
What sets the switch point. The authors conclude that thermal stability mechanisms "are related to polymer substituent groups": protic substituents such as those of cellulose derivatives are "prone to catalyze" degradation, while Tg, loading and molecular weight showed no direct relationship to degradation. ·
Conclusion drawn. Of the three hypotheses, drug–polymer compatibility "was found to have the most consequential influence"; the abstract states that the dehydration-hydrolysis series "led to" faster degradation with protic and slower with aprotic polymers.
06What it means for formulation
- Aprotic PVP and PVP/VA gave RTV better thermal stability than protic cellulose polymers.
- TGA assay can rank-order drug–polymer compatibility but overpredicts degradation; couple it with actual HME.
- A convection oven "may be" a better material-sparing screen.
- For a heat-labile drug, the polymer's own reactive groups matter more than its Tg.
More detail
- Polymers with protic substituents such as cellulose derivatives are "prone to catalyze" RTV degradation; aprotic PVP and PVP/VA improved its thermal stability.
- Isothermal TGA with assay is useful to rank-order drug–polymer compatibility and to study mechanisms, but overpredicts degradation and could wrongly rule out a formulation; TGA mass loss is not a reliable guide; it is "essential" to couple such tests with actual HME. ·
- Conclusions about thermal stability from nonisothermal TGA alone "may be misleading".
- A convection oven "may be a more appropriate material-sparing approach" for thermal degradation screening, as its results were closer to HME.
- PVP K-30 protected best but needs higher extrusion temperatures because of its high Tg and viscosity, so PVP/VA 64 was the extrudable choice.
- For a drug that hydrolyses, check the polymer's own chemistry (acid-forming esters, protic groups) before relying on a higher-Tg grade: in this paper, changing Tg by grade or loading did not change degradation, changing the polymer family did.
- A 5 min isothermal TGA hold here overstated losses several-fold compared with extrusion at the same temperature; its usable output is the rank order, not the number.
- HPMCAS and HPMC, often chosen for crystallization inhibition, carried a chemical-stability cost for ritonavir at extrusion temperatures; for such a drug, processing temperature and polymer family need to be screened together.
07Open questions
- How much do the polymers themselves degrade, and does that feed RTV degradation?
- Why does HPMC, without acetyl or succinoyl groups, degrade RTV most?
- Does P4 really form first and release the water that drives the rest?
More detail
- The polymers may degrade during heating; their degradation extent and mechanisms were not studied.
- Why TGA overpredicts: temperature history during heating and cooling, or the nitrogen purge removing volatile products and pushing degradation forward.
- The acid-release argument fits HPMCAS but not HPMC, which has no acetyl or succinoyl groups yet was the most destabilizing; no acid, acidity or polymer degradation product was measured.
- No time course of individual degradants or water measurement tests whether P4 forms first.
- Loading and grade were tested with ANOVAs pooled over temperature; whether they matter at 170–180 °C, where the plotted assays spread, is open.
- The PVP/VA 37 result could reflect its vinyl acetate (an acetate ester) rather than less PVP.
- The water content of the ASDs before heating, which matters for a hydrolytic mechanism, is not reported.
- One drug, mostly one loading, and HME at small scale with three polymers. ·
08How solid
AI assessment, not a statement made in the paperThe polymer ranking is measured directly and recurs in TGA, oven and HME, and the degradant masses fit their formulas. But the mechanism offered for it, water from P4 and acid from protic polymers, was not measured, HPMC does not fit the acid argument, and the "no effect" of loading and grade rests on ANOVAs pooled over temperature. ·····
More detail
- The polymer ranking is a direct assay result across seven temperatures and recurs in HME and in the oven at 160 °C. ··
- Mass loss and assay are compared on the same samples, which shows directly that mass loss misranks the systems. ·
- Degradant formulas fit exact masses within 5 ppm, and four of the seven degradants match earlier hydrolysis studies. ·
- Phase state was checked by DSC and XRPD for every ASD and extrudate. ·
- No measurement addresses the proposed mechanism: no acid release, acidity, water content or degradant time course; HPMC lacks the acid-forming groups the argument relies on. ·
- The ANOVAs pool all temperatures, so "no DL or grade effect" is not shown at 170–180 °C; PVP/VA 37 was not tested statistically. ·
- Text and figures disagree in places: Tg ranges for the PVP ASDs, the Tg trend across polymers, the same PVP K-30 sample plotted with different values, and degradant labels in Fig. S12. ···
- The 5 min oven and TGA values compared with HME come from fits, and TGA runs at 160 °C differ by up to about 8 points; HME exposure is shorter than its nominal 5 min for much of the melt. ·
- The TGA assays carry no error bars, the neat RTV form is not stated, and the new degradant structures rest on mass spectra only. ·
09Figure guide
Every figure and table of the paper, what it is there for, and what to check on the original. Key figures are shown with the story.
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Fig. 1 (p.333)key figure | Defines the systems: RTV, PVP, PVP/VA and the substituents of HPMC and HPMCAS.·· | 0.2 | |
| Table 1 (p.335) | Tg of the neat polymers and of the 20% DL ASDs, the basis of the mobility test. | F2 | Text ranges for the PVP ASDs disagree with the table. |
| Table 2 (p.335) | Tg falls with loading for PVP K-30 and PVP/VA 64 ASDs. | F2 | |
| Fig. 2 (p.335)key figure | Nonisothermal TGA of RTV and isothermal mass loss at 180 °C.· | F5, K7 | |
| Fig. 3 (p.336)key figure | The central result: RTV assay vs temperature for each polymer, and the degradant chromatogram.· | F1, K1 | Up to 150 °C the PVP systems and neat RTV do not differ. |
| Fig. 4 (p.336)key figure | Assay across 10–50% DL for PVP K-30 and PVP/VA 64. | F2, K2 | The ANOVA pools temperatures; at 180 °C PVP/VA 64 falls with loading. |
| Fig. 5 (p.336)key figure | Assay across PVP and PVP/VA grades.· | F2, K2 | PVP K-30 values differ from Fig. 3A; PVP/VA 37 not tested statistically.· |
| Fig. 6 (p.337)key figure | Assay vs T/Tg: no common curve. | F2, K2 | Results and discussion disagree on the Tg trend across polymers. |
| Fig. 7 (p.338)key figure | HME assay and summed degradant area at 130–160 °C. | F6, K6 | Assays at 130–140 °C overlap within error. |
| Fig. 8 (p.338)key figure | Oven vs TGA time course at 160 °C. | F6, K6 | |
| Fig. 9 (p.339)key figure | FT-IR of PVP and PVP/VA systems: small changes only. | F3, K4 | |
| Table 3 (p.339)key figure | Exact masses and formulas of RTV and P1–P7. | F4, K5 | Two theoretical masses and one error do not match their formulas. |
| Fig. 10 (p.340)key figure | Proposed acid-catalysed pathways to P1–P7.· | 0.5, K5 | A schematic, not data. |
More detail
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Tables S1–S2 (SI p.2) | One-way ANOVAs across loadings and grades.· | F2, K2 | Each group pools seven temperatures. |
| Fig. S1 (SI p.3) | Schematic of the extruder. | 0.2 | A schematic, not data. |
| Fig. S2 (SI p.4) | HPLC calibration, linear from 5 to 350 µg/mL. | ||
| Figs. S3–S5 (SI p.5–7) | DSC and XRPD: one Tg, amorphous ASDs and extrudates. | 0.4 | |
| Fig. S6 (SI p.8) | Onset of degradation of neat RTV, 135–214 °C. | F5 | |
| Figs. S7–S9 (SI p.9–11) | Mass loss over 60 min of the ASDs, the loading series and the polymers.·· | F5, K7 | |
| Fig. S10 (SI p.12) | Chromatograms of all degraded sets; P4 the largest degradant peak. | F4, K5 | |
| Figs. S11–S12 (SI p.13) | Extrudate photographs and chromatograms.· | F6 | Peaks labelled P1–P3 in Fig. S12 are P4–P6 of the text. |
| Fig. S13 (SI p.14) | First-order fits for oven and TGA. | F6, K6 | The 5 min values in the text come from these fits. |
| Fig. S14 (SI p.15) | FT-IR of HPMC and HPMCAS systems. | F3, K4 | |
| Figs. S15–S16 (SI p.16–17) | MS spectra of RTV and P1–P7. | F4 | P2 retention time differs between text and spectrum. |
| Fig. S17 (SI p.18) | Proposed fragmentation pathways. | F4 | A schematic, not data. |