Can fluorescence probes detect amorphous phase separation, and its length scale, in 40:60 ITZ–HPMC dispersions dried at different rates, including spray-dried powder?
Detection, yes: pyrene reported a pure-ITZ environment in every dispersion, and confocal imaging and ssNMR agreed. Size, only partly: imaging sized the film domains (about 3–5 μm cast, about 1 μm spin coated); for spray-dried powder only ssNMR bounded it (mixed at about 30–130 nm, not at 2–8 nm). ····
For 40:60 itraconazole–HPMC dispersions made from one methanol–dichloromethane solution by film casting, spin coating, rotary evaporation and spray drying, the authors conclude that all were phase separated into discrete drug-rich domains in a polymer-rich continuous phase ("demonstrated"), although DSC of the powders gave a single Tg, and that the domains were larger the slower the solvent was removed, from micrometres in cast films to the nanometre scale in spray-dried powder. ··· They find the fluorescence probes "sensitive and rapid" in detecting this phase separation "even at the nanoscale" and promising for spray-dried ASDs, whose domains confocal imaging cannot resolve, and suggest pyrene as a rapid screen for polymer and solvent selection ("may be useful"); ssNMR relaxometry served as the orthogonal check and supplied the size information. ···· Proposed but not measured: that faster evaporation gives smaller domains through faster supersaturation and a higher nucleation rate of the drug-rich phase ("is expected to"), and that heating during DSC remixes the phases into one Tg ("can potentially"); the effect of the domains on crystallization and dissolution was not tested. ···
01Why this study
The polymer inhibits crystallization only when mixed with the drug molecularly; amorphous–amorphous phase separation (AAPS) leaves polymer-poor drug-rich domains that crystallize faster.
Rumondor 2009, ref 12
DSC cannot resolve domains below about 15–30 nm, and it has given one Tg for dispersions phase separated at the micron scale.
Krause 1977, ref 40; Qian 2010, ref 14 ··
Spin-coated ITZ–HPMC films looked miscible by DSC but phase separated by AFM, nano-infrared and fluorescence; those methods suit films, not spray-dried particles.
Purohit 2015a, ref 15; Six 2003, ref 21 ·
Its I1/I3 ratio falls in less polar surroundings, and a miscible dispersion gives a value between those of drug and polymer.
Kalyanasundaram 1977, ref 23; Purohit 2015b, ref 19
More detail
What was already known. The introduction and discussion build on these points:
- Why miscibility matters. An ASD holds the drug in a high-energy, non-crystalline form that can crystallize; the polymer is chosen to prevent this, which needs molecular-level mixing so that it can disrupt drug self-assembly. Immiscibility appears either as crystals or as AAPS, in which both phases stay amorphous. AAPS lowers the polymer content of the drug-rich domains and can speed crystallization, giving poor or unpredictable dissolution; a hydrophobic drug-rich phase also wets poorly and dissolves more slowly. (refs 4–13; Rumondor 2009, ref 12)
- Where phase separation comes from. It can arise from the manufacturing process (spray drying or hot-melt extrusion), from moisture taken up during storage, or on contact with dissolution medium. (Qian 2010, ref 14; Rumondor 2009, ref 12; Purohit 2015b, ref 19)
- Standard tests miss it. DSC and XRD detect crystals well but not amorphous heterogeneity. SEM and AFM see only surfaces and cannot tell drug from polymer; infrared and Raman spectra can be hard to interpret and do not suit every system. (refs 14–18)
- Limits of DSC. The single-Tg criterion "often provides ambiguous results". Its resolution limit is about 15–30 nm (Krause 1977, ref 40); Qian et al. found one Tg in dispersions phase separated at the micron scale (Qian 2010, ref 14); two Tgs have been recorded in blends shown miscible by neutron scattering (Lodge 2006, ref 42). DSC is also non-isothermal: heating towards Tg raises mobility and miscibility and "can potentially" remix a phase-separated sample. ···
- ITZ–HPMC is known to separate. Earlier work found limited ITZ–HPMC miscibility after solvent evaporation. Spin-coated films were miscible by DSC criteria but phase separated by AFM, nano-infrared spectroscopy, fluorescence imaging and spectroscopy, and nano-thermal analysis. These high-resolution methods were applied to spin-coated films and are hard to apply to particles, especially spray-dried ones; steady-state fluorescence is the exception. (Purohit 2015a, ref 15; Six 2003, ref 21) ·
- Fluorescence probes. Fluorescence had begun to be used for miscibility in amorphous systems (refs 15, 19, 20, 43). Pyrene's I1/I3 ratio is lower in less polar media and higher in more polar ones; in a miscible ASD it falls between the values for pure drug and pure polymer. (Kalyanasundaram 1977, ref 23; Purohit 2015b, ref 19; Tian 2016, ref 20)
- ssNMR relaxometry. Spin diffusion averages the 1H relaxation times of intimately mixed components to one value, while immiscible components keep distinct values; T1 and T1rho test this over two length scales. In nifedipine–PVP, 90% drug loading gave distinct relaxation times (Δ = 0.4 s for T1, 13 ms for T1rho), while 60% and 50% loading gave almost identical values and a domain size of about 4.5 nm. (refs 25–29; Clauss 1993, ref 26; Yuan 2013, ref 39) ·
What the paper set out to do. Extend the earlier ITZ–HPMC work to test whether fluorescence dyes reveal miscibility and the size of phase-separated domains in ASDs made by film casting, spin coating, rotary evaporation and spray drying. The working hypothesis: if AAPS occurs, non-polar probes go to the drug-rich phase and more polar probes to the polymer-rich phase ("It is hypothesized"). Because fluorescence methods were new for this purpose, ssNMR was added as an orthogonal check. ·
02How they approached it
One drug–polymer pair known to separate, at one ratio (40:60 w/w) and from one solution, dried at four rates; three probes of different polarity report where drug and polymer sit, and ssNMR checks the result. ··
What was done
One 40:60 ITZ–HPMC solution in methanol:dichloromethane→dried by four routes: film casting (about 5 min), spin coating (about 30 s), rotary evaporation, spray drying→with and without probe.
XRD and DSC of rotary-evaporated and spray-dried powder→amorphous state and Tg.·
Pyrene I1/I3 in three dispersions and in pure ITZ and HPMC→drug-like or intermediate surroundings.·
Films stained with prodan (non-polar) and R6G (polar)→confocal imaging→which phase is discrete, and its size.·
ssNMR 1H T1 and T1rho of ITZ and HPMC in spray-dried and film-cast dispersions→spin-diffusion lengths: mixed or not over tens of nanometres and a few nanometres.··
Domain size by route across confocal imaging and ssNMR (Table III, Fig. 10); single DSC Tg set against the fluorescence result.··
More detail
What was done
- Feed solution. ITZ and HPMC-606 (40:60 w/w) were dissolved in 1:1 v/v methanol:dichloromethane at 2% w/v solids. Part of the solution received 0.2% w/w of one probe (pyrene, prodan or R6G) for fluorescence work; the rest stayed probe-free for DSC, XRD and ssNMR. The spray-drying section instead states 2% w/w solids and 0.1% w/w pyrene. ··
- Film casting (slow). Solutions were cast on quartz coverslips and Teflon sheets, left 10 min in a fume hood and then dried 24 h under vacuum; primary drying took about 5 min. Quartz films served fluorescence and confocal work; Teflon films were cryomilled for ssNMR.
- Spin coating (fast). 100 μL was spun at 300 rpm for 30 s on quartz and vacuum-dried 24 h; primary drying took about 30 s, with most solvent leaving in under 10 s.
- Rotary evaporation (fast). Solvent was removed under reduced pressure at 50 °C; the solid was dried 24 h under vacuum and cryomilled to 150–250 μm.
- Spray drying (very fast). 5 g solids were sprayed at 2 mL/min (inlet 75 ± 4 °C, outlet 50 ± 4 °C, atomization air 1.5 L/min, drying gas 0.4 m³/min) on a ProCepT Micro Spray Dryer and kept overnight in a vacuum oven; batches were made with and without pyrene.
- Solid-state checks. Modulated DSC at 2 °C/min to 170 °C (and 10 °C/min, data not shown) and powder XRD (5–35° 2θ) were run on the rotary-evaporated and spray-dried powders; the spray-dried powder was also X-rayed after heating at 2 °C/min. SEM imaged the spray-dried particles. ····
- Steady-state fluorescence. Pyrene samples were excited at 332 nm and I1/I3 read from the emission spectrum; prodan and R6G films were excited at 407 and 561 nm, the confocal laser lines. Spray-dried ASDs at 10–50% drug loading were also measured. ·
- Confocal imaging. Films containing both prodan and R6G were imaged with a 60× oil objective (prodan: 407 nm excitation, 425–475 nm emission; R6G: 561 nm, 570–620 nm), separately and overlaid; the theoretical resolution was about 135 nm. Domains in spin-coated films were sized in ImageJ.
- ssNMR. 13C CP-MAS spectra of HPMC, amorphous ITZ, the spray-dried ASD and the milled film-cast ASD were recorded at 293 K and 12 kHz spinning; 1H T1 and T1rho were read through resolved ITZ and HPMC carbon peaks and averaged per component. ··
- Domain size from relaxation. Each relaxation time was converted to a spin-diffusion length, L = √(6Dt), with two diffusion coefficients (8.0 × 10⁻¹² cm²/s for rigid and 0.5 × 10⁻¹² cm²/s for mobile systems) giving a range. ·
Key equations
The intensity of each resolved 13C peak falls as the spin-lock time τ grows; a single-exponential fit gives the rotating-frame relaxation time T1rho of ITZ or HPMC. The decay curves and fitted I0 are not shown, only the averaged T1rho in Table II.·
The distance L over which 1H magnetization spreads during a relaxation time t; with D = 0.5 × 10⁻¹² or 8.0 × 10⁻¹² cm²/s, T1 gives 29–130 nm and T1rho 1–9 nm. Equal ITZ and HPMC relaxation times mean mixing over that length, and the paper reads its ssNMR domain sizes from these two lengths.··
Terms used on this page
- AAPS (amorphous–amorphous phase separation): drug and polymer split into a drug-rich and a polymer-rich phase, both still amorphous.
- Single-Tg criterion: one glass transition between those of drug and polymer, taken as a sign of miscibility.
- Pyrene I1/I3: ratio of the first to the third vibronic peak of pyrene emission; lower in non-polar, higher in polar surroundings.
- Excimer / exciplex: a broad, red-shifted emission from an excited pyrene paired with a second pyrene (excimer) or with another molecule (exciplex) at close range.
- Prodan: a hydrophobic dye whose emission shifts with polarity; shown blue in the confocal images.
- R6G (rhodamine 6G): a cationic, relatively hydrophilic dye; shown red in the confocal images.
- T1 and T1rho: 1H relaxation times in the laboratory and the rotating frame. Spin diffusion averages them across a well-mixed region; T1 reports on tens of nanometres, T1rho on a few nanometres.
- Δ: the ITZ–HPMC difference in a relaxation time; near zero means mixed on that length scale.
- Nucleation and growth vs spinodal decomposition: two ways a new phase forms; the first gives discrete round domains, the second an interconnected pattern.
- Primary drying: the main solvent-loss step of a drying process.
03Main findings
By DSC and XRD the dispersions look amorphous and miscible
Rotary-evaporated and spray-dried dispersions gave only an X-ray halo and one broad Tg at 87 °C, above that of amorphous ITZ (about 60 °C, cited). ··
More detail
Both powders showed a broad halo with no sharp peaks (maximum about 19° 2θ rotary-evaporated, about 18° spray-dried). Modulated DSC at 2 °C/min gave one broad Tg step with a midpoint of 87 °C for both (arrows in Fig. 3 at about 90 and 88 °C); pure amorphous ITZ has a midpoint Tg of about 60 °C (ref 31). By DSC criteria these dispersions are miscible. ··· The spray-dried trace also showed a small, sharp endotherm at about 165 °C, near the melting point of ITZ; it was absent at 10 °C/min and absent from the rotary-evaporated trace. Spray-dried powder heated at 2 °C/min showed ITZ crystal peaks (about 14.6, 17.6, 18.1, 20.5 and 23.6° 2θ), so the authors assign the endotherm to crystallization during the slow scan and take the fresh dispersions as amorphous. ··· Film-cast and spin-coated samples were not tested by DSC or XRD.
Pyrene sees pure ITZ in every dispersion
Pyrene I1/I3 was 1.38–1.39 in rotary-evaporated, film-cast and spray-dried dispersions: equal to ITZ alone (1.39), not between ITZ and HPMC (1.54). The authors conclude that all are phase separated. ··
More detail
Table I: ITZ alone 1.39, HPMC alone 1.54, rotary-evaporated ASD 1.38, film-cast ASD 1.39, spray-dried ASD 1.39, all with standard deviations of 0.02 or less (number of replicates not printed); pyrene in water gives about 1.90. A molecularly mixed dispersion should give an intermediate value; instead every dispersion matched pure ITZ, regardless of evaporation rate. Spray-dried dispersions at 10–50% drug loading gave similar ratios (values not shown). No spin-coated value was reported. ···
The authors' reading: non-polar pyrene "will preferentially partition in the less polar drug-rich ITZ phase, given sufficient mobility", so a partly or fully immiscible dispersion reads like the pure drug; the I1/I3 values "indicate" that all samples are phase separated. ·
The spray-dried spectrum (Fig. 5) also showed a broad band at about 445–470 nm (470 nm in the text), assigned to an excimer or exciplex. With about 116 ITZ molecules per pyrene, the authors find a pyrene–pyrene origin "unlikely" and read the band as evidence that pyrene sits within about 10 Å of ITZ, consistent with pyrene concentrated in ITZ-rich domains. Only the spray-dried spectrum is shown, although the text says the band appeared in all dispersions. ····
Two dyes show drug-rich islands in a continuous polymer-rich phase
In both film types, prodan sat in discrete round domains and R6G in the continuous phase, so the discrete phase is drug-rich ("Thus it is clear"). Prodan's emission in the dispersion (about 438 nm) matched ITZ (about 435 nm), not HPMC (about 451 nm). ···
More detail
Prodan emission peaked at about 435 nm in ITZ, about 451 nm in HPMC and about 438 nm in the dispersion film, whose spectrum shape matched ITZ; the authors read this as prodan in an ITZ-rich environment, in line with pyrene. ·
R6G excitation and emission overlap, so its emission was collected only at 570–620 nm, which still gave bright images. The text reports much lower R6G emission in pure ITZ films than in HPMC or dispersion films and explains it by R6G being poorly miscible with ITZ and self-aggregating ("it is likely"), which "suggests" that R6G favours HPMC; in the plotted window of Fig. 7 the ITZ trace is only slightly lower. ····
In confocal images of cast and spin-coated films, R6G stained the continuous phase, with dark unstained areas, and prodan stained discrete circular domains, leaving large areas unstained; overlays from simultaneous 407 and 561 nm excitation showed the same split. Together with earlier work showing that ITZ forms the discrete phase in solvent-evaporated ITZ–HPMC, the authors conclude that the discrete phase is drug-rich and the continuous phase polymer-rich. ···· They present the images as visual confirmation of the pyrene result for cast films, with added chemical specificity.
Faster drying gives smaller domains in films
Drug-rich domains were about 3–5 μm in slowly cast films and about 0.4–1 μm in spin-coated films (ImageJ D50 0.9 μm). ···
See also Fig. 8
More detail
The text gives the cast-film domains as "around 5 μm" (Results) and "~3–5 μm" (Discussion); larger prodan regions in cast films were built of smaller aggregates (circled in Fig. 8). Spin-coated domains were "1 μm" (Results) and "~400 nm–1 μm" (Discussion). ImageJ analysis of spin-coated films (watershed separation, circularity filter) gave a smallest domain of 300 nm, a largest of 2.8 μm, D50 0.9 μm and D90 1.5 μm; the number of domains analysed is not printed. The smallest size agrees with the earlier AFM study of similar films. ····
Primary drying took about 5 min for cast films and about 30 s for spin coating, with most solvent leaving in under 10 s. The authors call the effect of evaporation on domain size "very apparent". The small domains and the microscope resolution allow no conclusion about aggregation in spin-coated films. ···
ssNMR: the cast film is separated on both length scales, the spray-dried powder only on the smaller one
Film cast: ITZ and HPMC differed in T1 (3.4 vs 2.9 s) and T1rho (6.6 vs 18.6 ms). Spray dried: T1 matched (3.5 vs 3.4 s) but T1rho did not (9.8 vs 12.6 ms), read as mixed at 30–130 nm but not at 2–8 nm. ··
More detail
13C CP-MAS spectra had broad peaks, consistent with amorphous samples, and the spray-dried and film-cast spectra were almost identical, which the authors take to mean that evaporation rate "presumably" does not change the molecular structure, though the dynamics "could potentially" differ. Well-separated ITZ and HPMC peaks allowed each component's relaxation to be read. ···
Table II (standard errors in parentheses): spray-dried ITZ/HPMC T1 3.5 (0.18) / 3.4 (0.05) s, Δ 0.1 s; T1rho 9.8 (0.58) / 12.6 (0.22) ms, Δ 2.8 ms. Film-cast T1 3.4 (0.12) / 2.9 (0.04) s, Δ 0.5 s; T1rho 6.6 (0.64) / 18.6 (0.35) ms, Δ 12 ms. Spin-diffusion lengths were 32–130 nm (T1) and 2–8 nm (T1rho) for the spray-dried sample and 29–129 and 1–9 nm for the film-cast sample; these ranges reproduce from L = √(6Dt). ·
For the film-cast dispersion, the different T1 and T1rho values are read as phase separation ("immiscible") at a length scale above 30 nm, supporting the fluorescence and confocal results. For the spray-dried dispersion, equal T1 and distinct T1rho "suggest" mixing on the 30–130 nm scale but not at 2–8 nm; Table II classes it "partially miscible". The authors state that a larger Δ means more extensive phase separation. ··
Domain size falls by about three orders of magnitude from cast film to spray-dried powder
The summary table gives 3–5 μm (film cast), 500 nm to 1 μm (spin coated) and 2–8 nm (spray dried); the spray-dried value is a bound from ssNMR, not a measured size. ···
More detail
Table III lists 3–5 μm for film-cast (fluorescence, confocal, ssNMR), 500 nm to 1 μm for spin-coated (fluorescence, confocal) and 2–8 nm for spray-dried dispersions (fluorescence, ssNMR); the Fig. 10 bars read about 4000, 500 and 10 nm on a log axis. The Abstract and Conclusions word it as domains below 10 nm in spray-dried and above 30 nm in slowly evaporated dispersions. ···
For the spray-dried powder, steady-state fluorescence detected phase separation but gave no size, and confocal imaging could not be used because the domains lie below its resolution (about 135 nm); only ssNMR gave size information. · From the film trend and the few-millisecond primary drying in a spray dryer, the authors had expected spray-dried domains "much smaller" than the 1 μm spin-coated ones ("we can anticipate"), and they call the ssNMR result "entirely consistent" with that expectation. ·· The sizes come from different techniques and samples and differ between text, Table III and Fig. 10, so the trend holds as orders of magnitude. ·
04Further observations
- Spray-dried particles were about 10–30 μm, many near-spherical with small surface nodules.
- The spray-dried powder crystallized during a slow DSC scan (2 °C/min) but showed no endotherm at 10 °C/min. ··
- R6G had to be read away from its emission maximum, at 570–620 nm. ·
- Spray-dried dispersions at 10–50% drug gave pyrene ratios similar to the 40:60 sample.
More detail
- Spray-dried particle shape. SEM showed particles of about 10–30 μm: near-spherical particles, many with small surface nodules, mixed with smaller collapsed or dimpled ones. (Fig. 4)
- Crystallization in the DSC pan. The endotherm at about 165 °C appeared only in the spray-dried trace at 2 °C/min, and XRD after heating at that rate showed ITZ crystal peaks; no endotherm appeared at 10 °C/min. ···
- R6G reading window. Excitation and emission of R6G overlap (small Stokes shift); the signal near the laser line was off-scale for all three films, so the confocal collected 570–620 nm only. ·
- Other loadings. Spray-dried dispersions with 10–50% drug gave I1/I3 similar to the 40:60 sample (values not shown).
- Same 13C spectra. Spray-dried and film-cast dispersions gave almost identical CP-MAS spectra, with all aromatic peaks from ITZ. ·
- Separate samples for each method. Fluorescence used probe-containing preparations and DSC, XRD and ssNMR used probe-free ones; the film-cast ssNMR sample was a cryomilled film cast on Teflon, not the quartz film that was imaged. ··
05How the authors connect the findings
More detail
- Pyrene and prodan are non-polar and R6G is cationic and relatively hydrophilic. If the dispersion has separated, pyrene "will preferentially partition" into the less polar ITZ-rich phase, given enough mobility, so I1/I3 reads like pure drug; a molecularly mixed dispersion would give an intermediate value. Prodan stains the ITZ-rich phase blue and R6G the HPMC-rich phase red. ··
- During drying, methanol and dichloromethane leave and the solutes concentrate; once a miscibility or solubility limit is reached, further evaporation makes a component separate. Phase separation can proceed by spinodal decomposition or by nucleation and growth; the discrete, circular drug-rich domains are read as "suggesting" nucleation and growth.
- In slowly cast films the drug-rich domains aggregated, so larger regions are made of smaller domains; this "indicates" that the domains form before the solvent has fully evaporated, while mobility is still high enough for aggregation.
- Faster evaporation "is expected to" generate supersaturation faster and so raise the nucleation rate, giving smaller drug-rich domains; the spin-coated films fit this.
Slow drying (cast film, about 5 min). few nuclei and time to grow → domains grow and aggregate to about 3–5 μm → visible by confocal → ITZ and HPMC differ in both T1 and T1rho, phase separated above 30 nm. ··
Very fast drying (spray drying, a few milliseconds). rapid supersaturation → domains "much smaller" than 1 μm ("we can speculate") → below the about 135 nm confocal resolution → pyrene still reads pure ITZ, and T1 matches while T1rho differs: mixed at 30–130 nm, not at 2–8 nm. ···
What sets the domain size. The rate of solvent removal in the process: primary drying took about 5 min for cast films, about 30 s for spin coating (most solvent gone in under 10 s), and a few milliseconds in a spray dryer (cited). ···
Why DSC misses it. DSC resolves domains only above about 15–30 nm, and in a non-isothermal scan the rising mobility near Tg, together with miscibility that usually increases with temperature, "can potentially lead to remixing with the polymer" and a single Tg even if the sample was phase separated at room temperature. In this study DSC gave a single Tg while fluorescence detected phase separation. ·
Conclusion drawn. The fluorescence methods "proved to be sensitive and rapid" in detecting phase separation "even at the nanoscale", and "show promise" for miscibility evaluation of spray-dried ASDs; ssNMR, as the orthogonal method, "confirmed" the fluorescence results and added domain-size information. ··
06What it means for formulation
- A single DSC Tg should not be taken as proof of miscibility; orthogonal methods are needed. ·
- Pyrene fluorescence "may be useful" as a rapid (under 1 min) screen for polymer and solvent selection.
- The same composition carried micrometre or nanometre domains depending on drying rate, so a miscibility result belongs to a process, not only to a drug–polymer pair.
- Pyrene I1/I3 tells whether a drug-rich environment exists, not how large it is: all routes gave 1.38–1.39.
More detail
- DSC gave a single Tg for the dispersions tested while the fluorescence methods detected phase separation; given this ambiguity, "it becomes important to establish orthogonal analytical techniques for miscibility determination". ··
- Fluorescence spectroscopy with suitable environment-sensitive probes is presented as a promising rapid, high-throughput way to assess sub-micron phase separation in spray-dried particles, which is otherwise hard to assess.
- Because analysis takes under 1 min and is easy, the approach "may be useful as a rapid screening method for polymer and solvent selection".
- Confocal imaging with several probes of different polarity gives formulation scientists "an additional sensitive and versatile analytical methodology" for the microstructure of drug–polymer blends.
- Phase separation weakens the polymer's crystallization inhibition and, for a hydrophobic drug, slows dissolution through poorer wetting; it can arise from the manufacturing process, storage moisture or contact with dissolution media. ·
- For ITZ–HPMC, the drying rate decided whether drug-rich domains were micrometres or nanometres across. A statement that a drug–polymer pair is "miscible" or "immiscible" should name the process and its drying rate.
- Fast drying shrank the domains but did not remove them: even the spray-dried powder was not mixed at the few-nanometre scale. For this pair, faster drying alone did not give a molecular-level mixture.
- Pyrene I1/I3 works as a yes/no test for a drug-rich environment. It gave the same value for micrometre and nanometre domains, so a size still needs imaging or ssNMR. The pure-component contrast here was small (1.39 vs 1.54), so pairs whose drug and polymer have similar polarity may be hard to resolve.
- Whether nanometre-scale separation in a spray-dried dispersion matters for stability or release was not tested here.
07Open questions
- How does evaporation rate change the molecular dynamics of the dispersion, given almost identical 13C spectra?
- The spray-dried domain size is only bounded, between about 2–8 and 32–130 nm.
- The effect of the domains on crystallization and dissolution was not tested.
More detail
- Evaporation rate did not change the 13C spectra, but the molecular dynamics "could potentially be affected and is of great interest for further exploration".
- Can the fluorescence approach guide polymer and solvent selection? It is proposed as a screen but was tried with one polymer and one solvent system.
- The spray-dried domain size is a bracket: equal T1 and distinct T1rho place it above about 2–8 nm and below about 32–130 nm, while Table III, Fig. 10, the Abstract and the Conclusions give 2–8 nm or below 10 nm.
- The smallest domain the pyrene I1/I3 method can detect was not measured.
- Domain formation was not observed during drying; nucleation and growth, formation before full solvent loss and the supersaturation argument are inferred from end-state images. ··
- Crystallization and dissolution of these dispersions were not measured.
- Pyrene spectra of pure ITZ and pure HPMC in the excimer region were not shown.
- Only one polymer (HPMC-606), one solvent system and mainly one ratio were examined; DSC and XRD covered two of the four routes. ·
08How solid
AI assessment, not a statement made in the paperPhase separation is well supported for cast films, where three methods agree, and reasonably for spray-dried powder (pyrene plus T1rho). The domain sizes are weaker: they mix techniques and samples, disagree between text, table and figure, and the spray-dried value is a bound. ·····
More detail
- For film-cast dispersions, pyrene I1/I3, two-probe confocal imaging and ssNMR relaxometry agree, and pure ITZ and HPMC references are included. ··
- The I1/I3 values are tight (standard deviation 0.02 or less) and the dispersion values sit on the ITZ value, clearly apart from HPMC.
- The ordering of domain size with drying rate is consistent across confocal imaging and ssNMR. ···
- The spin-diffusion length ranges in Table II reproduce from the printed relaxation times.
- The spray-dried size is a bracket between two diffusion lengths, presented as a measured 2–8 nm or below 10 nm.
- Domain sizes for the same route differ between text, Table III and Fig. 10, and the cross-route comparison mixes confocal sizes of quartz films with ssNMR lengths of spray-dried powder and a milled Teflon-cast film. ·
- Amorphousness and the single Tg rest on DSC and XRD of two of the four routes.
- The pyrene–ITZ exciplex assignment uses the spray-dried spectrum only; reference spectra are not shown.
- The lower R6G emission in ITZ is stated but not quantified by Fig. 7.
- The pyrene level in films and rotary-evaporated samples (0.1 or 0.2% w/w) is unresolved, reference-sample preparation is not described, and no spin-coated I1/I3 exists although the Methods list one; replicate numbers are not printed. ···
- The formation mechanism is inferred from end-state images. ··
- The general length scales quoted for T1 and T1rho (20–100 and 1–20 nm) do not follow from the paper's own equation.
09Figure guide
Every figure and table of the paper, what it is there for, and what to check on the original. Key figures are shown with the story.
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Fig. 1 (p.3)key figure | Defines the materials: structures of R6G, pyrene, prodan, HPMC and ITZ. | 0.2 | Pyrene is drawn with two saturated ring positions; the text names pyrene. |
| Fig. 2 (p.5)key figure | Shows the fresh rotary-evaporated and spray-dried powders are X-ray amorphous, and that ITZ crystallizes when the spray-dried powder is heated at 2 °C/min.· | F1 | |
| Fig. 3 (p.5)key figure | The single-Tg result: one broad step, midpoint 87 °C, in both powders, plus an endotherm near 165 °C in the spray-dried trace, assigned to crystals formed during the scan.·· | F1, K5 | DSC covered two of the four routes only. |
| Fig. 4 (p.6)key figure | Spray-dried particles of about 10–30 μm, many near-spherical with surface nodules. | 0.4 | |
| Fig. 5 (p.6)key figure | Pyrene spectrum of the spray-dried powder: the I1 and I3 peaks behind Table I and a broad excimer/exciplex band at about 445–470 nm. | F2, K6 | Only the spray-dried spectrum is shown; reference spectra are missing. |
| Table I (p.6) | The key detection result: pyrene I1/I3 of 1.38–1.39 in three dispersions, equal to ITZ (1.39), not between ITZ and HPMC (1.54). | F2, K1, K5 | No spin-coated value although the Methods list one; pyrene level 0.1 or 0.2% w/w unresolved.· |
| Fig. 6 (p.7)key figure | Identifies the phase prodan reports: in the dispersion film it emits near ITZ (about 438 vs 435 nm), not HPMC (about 451 nm). | F3, K2 | Preparation of the reference films is not described. |
| Fig. 7 (p.7)key figure | R6G emission in ITZ, HPMC and dispersion films, with the 570–620 nm confocal window. | F3, K2 | The text's much lower R6G emission in ITZ is not visible in the plotted window. |
| Fig. 8 (p.8)key figure | The images: prodan in discrete drug-rich domains, R6G in the continuous phase; domains about 3–5 μm in cast and about 1 μm in spin-coated films.· | F3, F4, K2, K3, K7 | Domain sizes differ between text passages and Table III. |
| Fig. 9 (p.9)key figure | 13C CP-MAS spectra: amorphous, nearly identical for spray-dried and film-cast dispersions, with resolved ITZ and HPMC peaks for relaxometry. | F5 | |
| Table II (p.9) | The ssNMR test: T1 and T1rho of ITZ and HPMC with spin-diffusion lengths; spray-dried differs only in T1rho, film-cast in both. | F5, K1, K4 | The spray-dried size is bracketed between 2–8 and 32–130 nm, not measured as 2–8 nm. |
| Table III (p.10) | Domain size by route and technique: 3–5 μm cast, 500 nm to 1 μm spin coated, 2–8 nm spray dried. | F6, K3 | Mixes confocal sizes of films with ssNMR lengths of powders; film-cast ssNMR gives only a lower bound.· |
| Fig. 10 (p.12)key figure | The summary trend: domain size by route on a log axis, about 4000, 500 and 10 nm. | F6, K3 | Bar heights differ from Table III (spray dried about 10 vs 2–8 nm). |