Do common surfactants in a pH 3 suspending medium promote or prevent crystallization of celecoxib from spray-dried celecoxib–HPMCAS ASD particles, and how do they act?
Both. Crystals appeared at 0.5 h with SDS and 1 h with Polysorbate 80; the surfactant-free, Poloxamer 188, Triton X100 and STC suspensions stayed crystal-free for 48 h. The authors propose that nucleation and drug leaching set the outcome. ··
For spray-dried celecoxib–HPMCAS LF particles (33.3% drug loading) suspended in pH 3 acid at 25 °C, each surfactant just above its CMC, the authors conclude that surfactant choice is "critical": SDS and Polysorbate 80 reduced stability by promoting crystallization of drug dissolved in the liquid, whereas STC and Triton X100 gave stable suspensions that crystallized only after about a week, apparently from the particles. ···· They propose that a surfactant acts through its effects on nucleation and on drug leaching, which both "appear to play a critical role", and that leaching "is likely" set by how much the surfactant dissolves HPMCAS. · Chain-like tails (SDS, Polysorbate 80, Poloxamer 188) sped nucleation in solution and bulky groups (STC, Triton X100) slowed it, which the authors find "conceivable" to reflect templating at interfaces. ·· Several links were proposed but not measured: interfacial templating and drug–surfactant binding, HPMCAS–SDS complexes, the HPMCAS level that "most likely explains" the Poloxamer 188 suspension's stability, and celecoxib solubility with leached polymer present. ····
01Why this study
An ASD gains solubility over the crystal but can crystallize and lose it, faster with heat, moisture and solvents.
Murdande 2010, ref 6; Rumondor 2011, ref 7
Polymers keep particles suspended and can act as anti-nucleants; surfactants are added to wet the particles.
Ilevbare 2012, ref 9a; Ozaki 2013, ref 9b
Additives in amorphous suspensions were studied mainly as polymeric crystallization inhibitors.
Yokoi 2005, ref 10
They can enhance nucleation, speed polymorph transformation and change crystal growth.
Canselier 1994, Rodríguez-Hornedo 2004, Garti 1997; ref 11
More detail
What was already known. The introduction builds on these points:
- Amorphous forms dissolve better but are unstable. The theoretical solubility of an amorphous form is usually several times that of the crystal (Murdande 2010, ref 6). Because it is thermodynamically unstable, the amorphous form tends to crystallize and lose this advantage, faster on exposure to heat, moisture and solvents (Rumondor 2011 and 2009, ref 7). Stabilizing additives are therefore mixed with the drug to make an ASD, often by spray drying (Dhirendra 2009, ref 8).
- ASDs are dosed as acidified suspensions in toxicology. Early safety studies need very high exposure, and ASD particles are usually given to animals as a suspension by oral gavage. With a polymer whose solubility depends on pH, an acidic medium keeps the polymer largely undissolved and the particles suspended. Crystallization must then be prevented for the life of the suspension; the authors note that the same applies to enteric-polymer ASDs sitting in the stomach before they reach the small intestine. (Introduction; authors' framing, no reference)
- Suspension media hold several additives. Polymers raise viscosity and keep particles suspended, surfactants improve wetting and rheology, and anti-nucleants such as polymers can retard crystallization, a risk that rises sharply once the formulation meets water (Ilevbare 2012, ref 9a; Ozaki 2013, ref 9b). Suspension formulation is largely empirical, often by high-throughput screening, and how each additive acts is poorly understood.
- Polymers were studied, surfactants neglected. Most studies examined polymeric additives as nucleation and growth inhibitors, for example HPMC and a sugar ester in an aqueous suspension of amorphous cefditoren pivoxil (Yokoi 2005, ref 10).
- Surfactants can promote crystallization. In crystallization and crystal engineering, surfactants have been shown to enhance nucleation, accelerate solution-mediated polymorph transformation and influence crystal growth (Canselier 1994, ref 11a; Rodríguez-Hornedo 2004, ref 11b; Garti 1997, ref 11c). The authors conclude that the effect of surfactants on amorphous suspensions deserves attention.
What the paper set out to do. Three objectives: (1) find out whether celecoxib crystallizes in or at the surface of the suspended ASD particles, or from solution after the drug leaches out; (2) evaluate how surfactants affect crystallization by studying their effect on celecoxib nucleation and on drug leaching; (3) relate surfactant structure to suspension stability. Five commonly used surfactants were compared in suspensions of a celecoxib–HPMCAS spray-dried ASD.
02How they approached it
One spray-dried ASD (celecoxib–HPMCAS LF, 33.3% drug loading) was suspended in pH 3 HCl with or without one of five surfactants, each just above its CMC, and their effects on nucleation, leaching and crystals were compared at 25 °C. ··
What was done
Spray-dry celecoxib–HPMCAS at 33.3% drug loading→PLM, XRPD and DSC confirm it is amorphous.···
Form III solubility against surfactant level in pH 3 HCl→CMC at each break point→test levels just above the CMC.·
Methanol shift to S = 5 in eight media, no ASD→light extinction at 350 nm→nucleation induction time.
10 mg/mL ASD suspensions in six media, 25 °C→polarized light microscopy for crystals over 48 h; XRPD of the SDS solids.·
Suspension liquid filtered over time→drug as supersaturation (HPLC) and HPMCAS (colorimetry, four media).·
Nucleation test repeated with 3 µg/mL HPMCAS in the SDS, Polysorbate 80 and Poloxamer 188 media.
For each surfactant, its effect on nucleation and on leaching set against the suspension outcome; promoters and inhibitors compared by tail shape.·
More detail
What was done
- The ASD. Celecoxib (20 mg/mL) and HPMCAS LF (40 mg/mL) were dissolved in acetone and spray-dried on a ProCepT Microspray dryer (0.8 mm two-fluid nozzle, 6 mL/min, inlet 85 ± 5 °C, outlet 55 ± 5 °C, atomizing air 4 L/min), then dried overnight under vacuum at room temperature. The drug loading was 33.3 w/w%. Amorphous character was checked by polarized light microscopy, XRPD and DSC (25–170 °C at 10 °C/min). ····
- Media. Milli-Q water was brought to pH 3 with 0.5 N HCl, and surfactant was added as % w/w.
- Solubility and CMC. Excess crystalline celecoxib (Form III) was stirred in 15 mL medium for 48 h at 25 °C, ultracentrifuged at 40,000 rpm and assayed by HPLC-UV at 250 nm. This was done over a range of each surfactant (SDS 0–0.40%, STC 0.10–1.50%, Polysorbate 80 0–1%, Triton X100 0–0.15%, Poloxamer 188 0.002–3%). Because a drug can shift the CMC, the CMC was read from these data, with celecoxib present at saturation, as the point where the two straight lines of solubility against surfactant concentration meet. Test levels were then set "11% above" each CMC. ····
- Nucleation induction time. Following the method of Ilevbare (ref 9a), a methanol stock of celecoxib (usually about 100 µL) was added to 50 mL medium stirred at 300 rpm at 25 °C. The amount gave a supersaturation of 5 relative to Form III solubility in that medium, so that the driving force was the same in every medium. Light extinction at 350 nm was followed with a fibre-optic dip probe, and the induction time was taken where lines through the flat and the rising parts of the trace intersect (Fig. 3). Each test was repeated at least three times; STC runs were followed for 16 h. Eight media were tested: the six suspension media plus SDS 0.175% and STC 0.4%, both below the CMC. ···
- Suspension stability. 100 mg ASD was added to 10 mL medium (10 mg/mL solids) in a 20 mL vial, held at 25 °C and stirred at 150 rpm. A drop was examined by polarized light microscopy at 0.5, 1, 2, 4, 6, 24 and 48 h; birefringent particles meant crystals. Solids from the SDS suspension were filtered, dried and examined by XRPD after 24 h. Some suspensions were also looked at after about 7 days. ···
- Drug and polymer leaching. At each time point a 10 mL suspension was filtered through a 0.45 µm nylon filter. Drug in the filtrate was assayed by HPLC and divided by the Form III solubility in that medium to give the supersaturation. HPMCAS in the filtrate was assayed by phenol–sulfuric acid colorimetry at 490 nm, in the SDS, STC, Triton X100 and surfactant-free media only. ··
- HPMCAS in the nucleation test. Induction times were measured again in the SDS, Polysorbate 80 and Poloxamer 188 media with 3 µg/mL HPMCAS added, chosen as just below the amount that leaches into the medium at pH 3. ·
Key equations
The drug concentration in solution C is divided by the Form III solubility C_eq measured in the same medium, so a surfactant that only solubilizes the drug does not raise S. The paper starts every nucleation test at S = 5 to give each medium the same driving force, and reports all suspension data as S, assuming that leached HPMCAS leaves C_eq largely unchanged.··
Terms used on this page
- Supersaturation (S): dissolved drug concentration divided by the equilibrium solubility of crystalline Form III in the same medium; S = 5 means five times saturated.
- Nucleation induction time (τ): time between creating a supersaturated solution and the first detectable crystals, here seen as a rise in light scattering.
- CMC (critical micelle concentration): the surfactant level at which micelles form; above it the surfactant solubilizes the drug much more strongly.
- Leaching: drug or polymer passing from the suspended ASD particles into the liquid.
- Form III: the crystalline celecoxib form used as the solubility reference; it grows as thin needles.
- Birefringence: crystals appear bright under crossed polarizers in the microscope; amorphous particles do not.
- Acidified suspension: HPMCAS is an enteric polymer, barely soluble at pH 3, so in acid the ASD particles stay as a suspension instead of dissolving.
03Main findings
SDS and Polysorbate 80 make the suspension crystallize within an hour
Celecoxib needles appeared at 0.5 h with 0.25% SDS and at 1 h with 0.0064% Polysorbate 80. The other four suspensions showed no crystals up to 48 h. ·
More detail
By polarized light microscopy, the SDS suspension contained crystals from the first check at 0.5 h and the Polysorbate 80 suspension from 1 h; both stayed crystalline to 48 h. The suspensions without surfactant or with Poloxamer 188 0.17%, Triton X100 0.025% or STC 0.75% showed no crystals at any time up to 48 h. In SDS, needle-like crystals floated in the liquid next to dark aggregates of ASD particles at 0.5 h; in Polysorbate 80 there were many thin needles at 1 h; in the other four media only particles and aggregates were seen at 48 h (Fig. 5). Solids filtered from the SDS suspension after 24 h gave XRPD peaks at the Form III positions on top of a raised halo, which the authors read as a mixture of Form III crystals and remaining ASD ("suggest"). · They also state that the needles grow along the crystal c-axis, without giving the basis for the peak indexing. · An XRPD pattern for the Polysorbate 80 solids is not shown.
The authors rank stability as STC ≈ Triton X100 ≈ no surfactant > Poloxamer 188 > Polysorbate 80 > SDS. Poloxamer 188 is placed lower because its supersaturation fell slowly (F3), although no crystals were seen. · The abstract says STC and Triton X100 "inhibit" crystallization of the suspensions; the surfactant-free suspension was also crystal-free over 48 h, so inhibition relative to no surfactant is shown only for nucleation in solution (F2). · Replicate numbers for the suspension tests are not stated.
In solution, three surfactants speed nucleation and two slow it
At equal supersaturation (S = 5), the induction time was 7 min with Polysorbate 80, 12 min with Poloxamer 188 and 41 min with SDS, against 88 min without surfactant; it was 273 min with Triton X100 and more than 960 min with 0.75% STC.
More detail
Mean induction times at S = 5 and 25 °C (at least three runs; error bars read from Fig. 4): Polysorbate 80 0.0064%, 7 min (about ±1); Poloxamer 188 0.17%, 12 min (about ±4); SDS 0.175%, 29 min (about ±13); SDS 0.25%, 41 min (about ±12); no surfactant, 88 min (about ±20); Triton X100 0.025%, 273 min (about ±19); STC 0.75%, more than 960 min. The authors therefore rank nucleation promotion as Polysorbate 80 > Poloxamer 188 > SDS, and class Triton X100 and STC as inhibitors. STC runs were followed for 16 h without any rise in scattered light, so its induction time, "although not accurately determined, appears to be" longer than 960 min.
The effects held below the CMC: SDS 0.175% still shortened the induction time (29 min), and STC 0.4% still lengthened it ("Interestingly"). The STC 0.4% value is unclear: its bar label reads 273 min, the same as Triton X100, but the bar runs to the 400-min axis limit with a lower whisker near 333 min, and the text gives no value. · A single SDS 0.25% trace gave τ = 38 min (Fig. 3). Crystals collected after every run were thin needles, "consistent with" Form III; no XRPD was done on them. · These tests used a methanol shift into 50 mL at 300 rpm with no ASD or polymer present, unlike the suspensions (10 mL, 150 rpm, 10 mg/mL ASD).
SDS drives the most drug into solution, which then crystallizes
In SDS the supersaturation peaked within 10 min (7.4 in the text, about 8.6 in the figure) and fell to about 3.2 by 1 h. In Polysorbate 80 it fell from 3.4 to 1.1 between 0.5 and 3 h. Both falls match the crystals seen. ··
More detail
Drug dissolved in the suspension liquid, divided by Form III solubility in each medium (Fig. 7; values read from the figure unless stated):
- SDS 0.25%. Text: about 107 µg/mL within 10 min (S 7.4), then a rapid fall to S 3.2 and a slight rise over the next 23 h. Figure: about 8.6 at about 5 min, 6.2 at 10 min, 4.3 at 0.5 h, 3.2 at 1 h, then a rise to about 5.1 at 24 h. ·
- Polysorbate 80 0.0064%. Text: S fell from 3.4 to 1.1 between 0.5 and 3 h. Figure: about 2.9 at 10–20 min, 3.35 at 0.5 h, 2.4 at 1 h, 1.3 at 2 h, 1.05 at 3 h and 0.85 at 24 h, slightly below saturation, which is within the uncertainty of the solubility used. ·
- No surfactant. About 4.3 at 0.5 h rising to 6.7 at 48 h.
- STC 0.75%. About 3.5 at 0.5 h rising to 4.9 at 48 h.
- Poloxamer 188 0.17%. About 2.8 at 0.5 h, rising to 4.2 at 4 h, then falling to 3.7 at 24 h and 2.8 at 48 h.
- Triton X100 0.025%. About 1.6 at 0.5 h, held at about 1.5–1.8 to 48 h.
The authors read the rises as drug leaching from the particles and the falls as crystallization. They call leaching greatest in SDS and lower in the surfactant-free, Polysorbate 80, STC and Poloxamer 188 media, whose maximum S of 3.4–5.4 was reached within six hours, and they call S in the surfactant-free and STC media "relatively constant". · The figure shows both of these media still rising and highest at 48 h. The slow fall in Poloxamer 188 "could be" crystallization so slow that the few crystals escaped the microscope. Leaching in Triton X100 was minor. The S values assume that leached HPMCAS does not change celecoxib solubility much, which was not tested and matters most in SDS, where HPMCAS reached about 860 µg/mL (F4). · Fig. 7 has no error bars and replicates are not stated.
SDS dissolves far more HPMCAS from the particles
After 24 h the liquid held about 860 µg/mL HPMCAS with SDS, about 43 with STC, about 6 with Triton X100 and about 3.5 without surfactant.
More detail
HPMCAS in the liquid over 24 h (Fig. 8, log scale; values read from the figure): with SDS it rose from about 35 µg/mL at about 0.1 h to 73 at 0.5 h, 420 at 4 h and 860 at 24 h; with STC from about 5.5 at 0.5 h to 48 at 4 h and 43 at 24 h; with Triton X100 from about 2.9 to 6.0; without surfactant from about 1.5 to 3.5. The authors describe considerable leaching in SDS, "more than 3 orders of magnitude" above the surfactant-free medium; the plotted values give about 250-fold at 24 h and about 50-fold at 0.5 h. · STC raised HPMCAS less than SDS, and Triton X100 gave a profile close to the surfactant-free medium. Polymer was not measured in the Polysorbate 80 and Poloxamer 188 media. Error bars are shown only for the surfactant-free medium, and the printed calibration range (2–20 mg/mL) lies far above the low values measured. ·
The authors attribute the SDS effect "most likely" to polymer–surfactant complexes, as reported for HPMC and SDS (Nilsson 1995, ref 17; Qi 2013, ref 18).
A trace of HPMCAS slows nucleation with Poloxamer 188 only
Adding 3 µg/mL HPMCAS lengthened the induction time with Poloxamer 188 from about 12 to 50 min. It did not lengthen it with SDS (about 41 to 26 min) or Polysorbate 80 (about 7 to 5 min).
More detail
At S = 5, with and without 3 µg/mL HPMCAS (Fig. 9, values read): SDS about 41 min (whiskers about 21–61) without and 26 min (about 16–36) with polymer; Polysorbate 80 about 7 (6–8) and 5.3 (5–6); Poloxamer 188 about 12 (8–16) and 50 (37–63). The authors see no change "within experimental error" for SDS and Polysorbate 80 and a "significantly" longer time for Poloxamer 188; no statistical test or number of runs is given for these tests. · The 3 µg/mL level was chosen as the lowest polymer level expected in the suspension liquid, just below what leaches at pH 3. The authors suggest that this effect "most likely explains" why the Poloxamer 188 suspension stayed crystal-free, especially as the real polymer level "is likely to be" higher; HPMCAS was not measured in that suspension.
Crystals grow in the liquid with SDS and Polysorbate 80, on the particles otherwise
With SDS and Polysorbate 80, long needles floated free of the ASD particles. In Triton X100, birefringence appeared on the particles themselves, without free needles, after about 7 days. ·
More detail
The authors take the free-floating needles in SDS and Polysorbate 80, not attached to ASD particles, as evidence that these surfactants promote crystallization of drug that has dissolved into the liquid. · After 7 days in Triton X100 0.025%, birefringent regions sat on or in the particles and no free needles were seen (Fig. 10). The authors state that without surfactant crystals appeared only after more than 7 days and "seem to" start from the particle matrix or surface, and that the STC and Triton X100 suspensions were stable for at least 7 days and crystallized from the particles rather than from solution. · These 7-day observations appear only in the Discussion, and only the Triton X100 image is shown.
04Further observations
- Each surfactant raised Form III solubility, from 1.1 µg/mL to 1.4–14.5 µg/mL at the test levels.
- CMCs measured with celecoxib present ranged from 0.0058% (Polysorbate 80) to 0.69% (STC).
- Without surfactant, S rose from about 4.3 to 6.7 over 48 h, the highest of all media, yet no crystals formed. ··
- With Poloxamer 188, S fell from about 4.2 to 2.8 after 4 h, with no crystals seen. ·
- The spray-dried ASD was amorphous, with one glass transition at 61 °C. ··
More detail
- Solubility at the test levels. Form III solubility at 25 °C was 14.5 µg/mL in SDS 0.25%, 5.8 in STC 0.75%, 3.7 in Triton X100 0.025%, 2.0 in Polysorbate 80 0.0064%, 1.4 in Poloxamer 188 0.17%, 1.7 in SDS 0.175%, 2.4 in STC 0.4% and 1.1 without surfactant ("It is obvious that the presence of surfactant enhances the drug solubility"). · The Polysorbate 80 and Poloxamer 188 values are at levels not listed in the SI tables, and the surfactant-free value is 1.2 µg/mL in two of the tables. ·
- Solubility curves. Above the CMC solubility climbed steeply: to 92.6 µg/mL at 0.40% SDS, 26.0 at 1.50% STC, 198.4 at 1% Polysorbate 80 and 59.6 at 0.15% Triton X100. Poloxamer 188 raised it only slightly, to 2.5 µg/mL at 3%. ····
- CMCs. With celecoxib at saturation in pH 3 HCl: SDS 0.23%, STC 0.69% (0.668% on the SI figure), Polysorbate 80 0.0058%, Poloxamer 188 0.16%, Triton X100 0.022%. · The Poloxamer 188 CMC rests on solubility changes of 0.1–0.2 µg/mL and is weakly determined. The test levels lie 6–14% above the printed CMCs, not exactly 11%.
- The surfactant-free control. From 1 h on, the surfactant-free medium had the highest supersaturation of all six media, rising to about 6.7 at 48 h, yet stayed crystal-free, although its induction time at S = 5 was 88 min. ····
- Absolute drug in solution. Multiplying the peak S by the solubility in each medium gives about 107–125 µg/mL in SDS, 28 in STC, 7.4 without surfactant and 6.7 in Triton X100 (extractor arithmetic).
- Poloxamer 188. S rose for 4 h to about 4.2, then fell slowly to about 2.8 by 48 h, while the microscope showed no crystals. ··
- The ASD. No birefringence; one glass transition at 61 °C (midpoint) and no melting near 165 °C, the melting point of Form III; a broad dip in the DSC baseline between about 65 and 125 °C is not discussed; XRPD showed only a broad halo. ··
05How the authors connect the findings
More detail
- Many ASDs use a polymer such as HPMCAS that dissolves poorly in acid, so in an acidic liquid the ASD forms a suspension. In the surfactant-free medium HPMCAS stayed at a few µg/mL. Drug and polymer can both leach from the particles; because the drug is amorphous, leaching can make a supersaturated solution, and its concentration drops if the drug then crystallizes. The polymer simply dissolves up to its solubility. ··
- The authors propose two major factors: the surfactant's effect on nucleation from the supersaturated solution, and its effect on drug leaching. At this "relatively low" drug loading, drug release "appears to be" controlled by the polymer, so a surfactant that dissolves more HPMCAS also releases more drug ("It is likely"). For SDS, the polymer dissolves "most likely" through polymer–surfactant complexes, as reported for HPMC–SDS (Nilsson 1995, ref 17; Qi 2013, ref 18). ··
SDS. It promotes nucleation and causes substantial leaching → the high supersaturation "of course also favors nucleation" → crystals grow from drug dissolved in the liquid, seen as free needles → the least stable suspension. ·
Polysorbate 80. It promotes nucleation most strongly in solution but leaches less drug → crystals appear slightly later (1 h) → slightly more stable than SDS.
Poloxamer 188. It promotes nucleation in solution and leaches about as much drug as Polysorbate 80 → yet the suspension stayed crystal-free for at least 48 h → HPMCAS leached from the particles lengthens the induction time about fourfold in this medium, which "most likely explains" the stability. ··
STC and Triton X100. They inhibit nucleation and cause only moderate (STC) or minor (Triton X100) leaching → supersaturation stays lower → the suspensions are stable for at least 48 h; after about 7 days crystals appear on the particles rather than in the liquid. ·
What makes a promoter or an inhibitor. The three promoters (Polysorbate 80, Poloxamer 188, SDS) all have a chain-like hydrophobic tail; the two inhibitors (Triton X100, STC) have a bulky hydrophobic group. A suspension has many interfaces on which surfactants can assemble into Langmuir–Blodgett-type films, and such assemblies have been reported to template crystal nucleation and growth (Weissbuch 1988, ref 15a; Bujan 2001, ref 15b); a flexible polydiacetylene film was shown to align with nucleating calcite (Berman 1995, ref 16). The authors find it "conceivable" that flexible linear chains align to promote celecoxib nucleation, which rigid bulky groups cannot, and that drug–surfactant interactions "may be" behind the inhibition. ·
Conclusion drawn. Surfactants can affect ASD suspension stability both by promoting crystallization of drug in the liquid and by helping drug leach out of the particles; surfactant choice is "clearly critical", and minimizing leaching is "clearly desirable". · The abstract states that promotion or inhibition "was found to be related" to these two effects.
06What it means for formulation
- SDS and Polysorbate 80 can make an ASD suspension fail; STC and Triton X100 "should be assessed" as alternative wetting agents. ·
- Pick a wetting agent for an acidified ASD suspension by its effect on nucleation and on polymer dissolution, not by how well it solubilizes: SDS solubilized most and failed first.
More detail
- For toxicity studies a suspension needs to be stable for a few hours, and celecoxib ASDs "would" meet this in a simple pH-adjusted medium.
- Surfactants are often needed for wetting and flow, but the "wrong" surfactant can reduce stability and cause loss of efficacy through crystallization, as with SDS and Polysorbate 80.
- STC and Triton X100 did not compromise stability and "should be assessed" as alternative wetting agents.
- Leaching of drug from the particles should be minimized.
- The effect of surfactants on ASD stability should be weighed carefully, with "a risk benefit analysis of using surfactants".
- A surfactant that dissolves the enteric polymer at low pH (here SDS with HPMCAS) defeats the purpose of acidifying the medium: the polymer no longer holds the drug back.
- A solution induction-time test at fixed supersaturation sorted the surfactants into promoters and inhibitors cheaply, but it mis-ranked Poloxamer 188 until the polymer was added. A screen should include the ASD polymer, or a short suspension hold.
- The surfactant-free suspension was the most supersaturated and still stayed amorphous for 48 h, so supersaturation alone did not predict failure here.
- The ranking holds for one drug, one polymer, 33.3% loading, 25 °C and one level of each surfactant. Surfactant placed inside the ASD or tablet, and gastric conditions, were not tested.
07Open questions
- Was the slow fall in supersaturation with Poloxamer 188 crystallization below the microscope's detection? ("could be")
- How much HPMCAS does the Poloxamer 188 suspension really hold? ("likely to be higher")
- Why the surfactant-free suspension stayed crystal-free at S up to about 6.7.
- No direct test of the tail-shape explanation. ·
More detail
- The slow fall in supersaturation with Poloxamer 188 "could be" crystallization that the microscope missed; no solid-state analysis was done.
- The real HPMCAS level in the Poloxamer 188 suspension is "likely to be higher" than the 3 µg/mL tested.
- The STC induction time was "not accurately determined".
- The two-factor account does not explain the surfactant-free control, which held S of about 4.3–6.7 for 48 h without crystals although its induction time at S = 5 was 88 min; nucleation with HPMCAS present was not tested in that medium.
- HPMCAS leaching was not measured with Polysorbate 80 or Poloxamer 188, and in supersaturation terms the polymer–leaching link does not hold across the four media measured.
- Surfactant assembly at interfaces, templated nucleation and drug–surfactant binding were not measured. ·
- Celecoxib solubility with leached HPMCAS present was not measured, although HPMCAS reached about 860 µg/mL in SDS.
- Only one drug, one polymer, one drug loading, one level per surfactant and 25 °C were examined, with no in vivo test. ·
08How solid
AI assessment, not a statement made in the paperThe main observation (SDS and Polysorbate 80 crystallize within an hour, the others stay clear for 48 h) agrees across microscopy, XRPD and drug concentrations. The two-factor explanation is weaker: it leaves the surfactant-free control unexplained, rests on polymer data from four media and one Poloxamer 188 comparison, and replicates are not stated. ······
More detail
- The microscopy time course, the free needles, the Form III XRPD of the SDS solids and the drops in supersaturation agree. ···
- Induction times are means of at least three runs, and the promoters and inhibitors separate clearly from the 88-min reference.
- Solubility tables carry standard deviations, and the printed SDS supersaturation and SDS CMC can be reproduced from the data. ······
- HPMCAS levels differ by more than two orders of magnitude between SDS and the surfactant-free medium, well beyond reading error.
- The account does not cover the surfactant-free control (high S, no crystals).
- The leaching–polymer link rests on four media and holds for absolute drug concentration, not for supersaturation.
- Supersaturation in SDS assumes that about 860 µg/mL HPMCAS leaves celecoxib solubility unchanged.
- The Poloxamer 188 polymer effect is one comparison without a statistical test or stated number of runs; the SDS error bars differ between Figs. 4 and 9 for the same mean.
- Several text values disagree with the figures: the SDS peak S, the STC 0.4% induction time, the "constant" S in the surfactant-free and STC media, and the "3 orders of magnitude" of HPMCAS. ···
- Replicates are not stated for the suspension, leaching and solubility data; Fig. 7 has no error bars.
- The tail-shape rule rests on five surfactants and no interfacial measurement; the "C20 tail" of Polysorbate 80 does not match the drawn structure. ·
- The STC CMC is printed two ways, the Poloxamer 188 CMC is weakly determined, and the HPMCAS calibration range is printed in mg/mL. ··
- The ≥7-day route observations are qualitative and imaged for Triton X100 only.
09Figure guide
Every figure and table of the paper, what it is there for, and what to check on the original. Key figures are shown with the story.
| Figure | What it does in the paper | Supports | Check (AI note) |
|---|---|---|---|
| Fig. 1 (p.5–6)key figure | Defines the systems: celecoxib, HPMCAS and five surfactants, with chain-like tails (SDS, Polysorbate 80, the PO block of Poloxamer 188) against bulky groups (Triton X100, STC). | 0.2, K3 | The text's "C20 tail" of Polysorbate 80 does not match the drawn 18-carbon chain. |
| Fig. 2 (p.11)key figure | Confirms the starting ASD is amorphous: no birefringence, one glass transition at 61 °C, an XRPD halo.·· | 0.4 | |
| Fig. 3 (p.13)key figure | Shows how an induction time is read: extinction at 350 nm stays flat, then rises; the fitted lines cross at 38 min in SDS 0.25%. | 0.2 | |
| Fig. 4 (p.14)key figure | The nucleation test: induction time at S = 5 in eight media, from 7 min (Polysorbate 80) to more than 960 min (STC 0.75%), against 88 min without surfactant. | F2, K2 | The STC 0.4% bar is labelled 273 min but drawn to the 400-min axis limit. |
| Table 1 (p.15) | The main outcome: crystals by PLM from 0.5 h in SDS and 1 h in Polysorbate 80, none to 48 h in the other four media. | F1, K1 | Replicates not stated. |
| Fig. 5 (p.15–16)key figure | What the microscope saw: free needles in SDS at 0.5 h and Polysorbate 80 at 1 h; only particles and aggregates at 48 h in the other four media. | F1, F6, K1, K7 | |
| Fig. 6 (p.16–17)key figure | Identifies the crystals: solids after 24 h in SDS show Form III peaks on an amorphous halo. | F1, K1 | No basis given for the peak indexing and the c-axis needle direction. |
| Fig. 7 (p.19)key figure | Drug supersaturation in the suspension liquid over 48 h: SDS peaks within 10 min and falls by 1 h, Polysorbate 80 falls by 3 h, the surfactant-free and STC media keep rising. | F3, K4, K6 | Text and figure disagree on the SDS peak and on the "constant" S; no error bars.·· |
| Fig. 8 (p.20)key figure | HPMCAS leached into the liquid: about 860 µg/mL with SDS at 24 h against about 43 (STC), 6 (Triton X100) and 3.5 (none). | F4, K4 | About 250-fold, not "3 orders of magnitude"; calibration range printed in mg/mL.· |
| Fig. 9 (p.24)key figure | Tests the polymer effect: 3 µg/mL HPMCAS lengthens the induction time with Poloxamer 188 (about 12 to 50 min) but not with SDS or Polysorbate 80. | F5, K5 | No statistical test or n; the SDS whiskers differ from Fig. 4. |
| Fig. 10 (p.26)key figure | Shows where crystals start without a promoter: birefringence on the particles after 7 days in Triton X100, no free needles. | F6, K7 | 7-day observations appear only in the Discussion; only this medium is imaged. |
| Tables S1–S5 (SI pdf p.1–6) | Form III solubility against each surfactant's concentration: the data behind the CMCs and the S normalisation. | 0.4 | The Polysorbate 80 and Poloxamer 188 test-level solubilities are not in the tables; the surfactant-free value is 1.1 or 1.2 µg/mL.· |
| Figs. S1–S5 (SI pdf p.1–6)key figure | Plots of Tables S1–S5 with each CMC marked at the break point. | 0.4 | STC CMC 0.668% on Fig. S2 but 0.69% in the text; the Poloxamer 188 CMC is weakly determined.· |